D-Link DES-3010G Reference Manual - Page 145

ECHNICAL, PECIFICATIONS, Physical and Environmental

Page 145 highlights

DES-3010F / DES-3010G / DES-3018 / DES-3026 Layer 2 Switch CLI Reference Manual A TECHNICAL SPECIFICATIONS Physical and Environmental AC input & External Redundant power Supply: 100 - 120; 200 - 240 VAC, 50/60 Hz (internal universal power supply) Power Consumption: DES-3010F - 10.7W DES-3010G - 9.9W DES-3018 - 10.5W DES-3026 - 11.6W Operating Temperature: 0 to 40 degrees Celsius Storage Temperature: -40 to 70 degrees Celsius Humidity: Operating: 5% to 95% RH non-condensing; Storage: 0% to 95% RH non-condensing Dimensions: DES-3010F/G - 280 mm x 180 mm x 44 mm (1U), 11 inch rack-mount width DES-3018/3026 - 441 mm x 207mm x 44 mm (1U), 19 inch rackmount width Weight: DES-3010F/G - 1.5kg DES-3018 and DES-3026 - 2.1 kg EMI: FCC Class A, CE Class A, C-Tick Class A Safety: CSA International 143

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

DES-3010F / DES-3010G / DES-3018 / DES-3026 Layer 2 Switch CLI Reference Manual
A
T
ECHNICAL
S
PECIFICATIONS
Physical and Environmental
100 – 120; 200 - 240 VAC, 50/60 Hz (internal universal power supply)
Power Consumption:
DES-3010F – 10.7W
DES-3010G – 9.9W
DES-3018 – 10.5W
DES-3026 – 11.6W
Operating Temperature:
0 to 40 degrees Celsius
Storage Temperature:
-40 to 70 degrees Celsius
Humidity:
Operating: 5% to 95% RH non-condensing;
Storage: 0% to 95% RH non-condensing
Dimensions:
DES-3010F/G - 280 mm x 180 mm x 44 mm (1U), 11 inch rack-mount
width
DES-3018/3026
- 441 mm x 207mm x 44 mm (1U), 19 inch rack-
mount width
Weight:
DES-3010F/G – 1.5kg
DES-3018 and DES-3026 - 2.1 kg
EMI:
FCC Class A, CE Class A, C-Tick Class A
Safety:
CSA International
AC input & External
Redundant power
Supply: