Dell PowerEdge 4300 Dell PowerEdge 4300 Systems Service Manual - Page 42
No memory installed - firmware
View all Dell PowerEdge 4300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
1-1-3 1-1-4 1-2-1 NVRAM write/read failure BIOS checksum failure Programmable interval-timer failure Replace the system board. This fatal error usually requires that you reflash the BIOS firmware. If the problem persists, replace the system board. Replace the system board. 1-2-2 DMA initialization failure 1-2-3 1-3-1 1-3-2 1-3-3 DMA page register write/read failure Main-memory refresh verification failure Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still persists, replace the system board. No memory installed Chip or data line failure in the first 64 KB of main memory Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still persists, replace the system board. 1-3-4 Odd/even logic failure in the first 64 KB of main memory 1-4-1 Address line failure in the first 64 KB of main memory 1-4-2 Parity failure in the first 64 KB of main memory 2-1-1 Bit failure in the first through 64 KB of main 2-4-4 memory 3-2 Dell PowerEdge 4300 Systems Service Manual