Dell PowerEdge 4300 Dell PowerEdge 4300 Systems Service Manual - Page 65
close-out panel for a 1.6-inch bay has a raised lip at the bottom that overlaps
![]() |
View all Dell PowerEdge 4300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
The chassis provides three bays for 5.25-inch externally accessible drives and a bay dedicated to a 3.5-inch diskette drive. front-panel inserts To remove the front-panel insert that covers an unused bay (see Figure 4-5), first remove the front bezel. Then, facing the inside of the front bezel, press one of the securing tabs (located at each end of the bezel) while pressing against the center of the insert until it springs free from the bezel. To replace a front-panel insert, from inside the chassis place the insert into the bay opening and press it into place until the tabs on each end of the insert snap into the latches on the inside of the bezel. Metal close-out panels that fit into the drive-bay openings in the chassis provide extra EMI shielding if you are not using the plastic front-panel inserts. The close-out panel for a 1.6-inch bay has a raised lip at the bottom that overlaps the top of a panel beneath it, if any. Because of the overlap, if two or more 1.6-inch close-out panels are installed, you must remove them from the top down. The close-out panel for the 1-inch diskette-drive bay (the top bay in either chassis orientation) is narrower and has no overlap lip. Removing and Replacing Parts 4-7