Dell PowerEdge 4300 Dell PowerEdge 4300 Systems Service Manual - Page 56
Ghwhfwhg, Idloxuh
View all Dell PowerEdge 4300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
A temperature probe on the backplane board, system board, or drive carrier in the specified server has exceeded its temperature warning range. If possible, the chassis number and probe number are provided. Make sure the fan thresholds are set in a reasonable range. Check for a fan failure. Make sure the computer cover is properly installed. A failure has occurred with the system power supply or voltage probe(s) on the system board. If possible, the chassis number and probe number are provided. Check the power supply and backplane board connections. The voltage probe on the backplane board, system board, or power supply for the specified server has exceeded its warning range. If possible, the chassis number and probe number are provided. Make sure the usersettable voltage thresholds are set correctly. If the problem persists, check the power supply and backplane board connections. 3-16 Dell PowerEdge 4300 Systems Service Manual