Dell PowerEdge 4300 Dell PowerEdge 4300 Systems Service Manual - Page 50
Gulyh, Lqwhuuxsw, Huuru, Glvnhwwh, Vxsso, Vxsso\²
View all Dell PowerEdge 4300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Incorrect configuration settings in System Setup program or no operating system on hard-disk drive Check the hard-disk drive configuration settings in the System Setup program. Defective system board Replace the system board. Faulty diskette, diskette/tape drive subsystem, or hard-disk drive subsystem Replace the diskette or hard-disk drive. If the problem persists, replace the system board. No operating system on diskette Use a bootable diskette. Attempted to run system with more than 512 MB of memory and only one power supply Install a PSPB with additional power supplies. Attempted to run two microprocessors with one power supply Install a PSPB with additional power supplies. Attempted to run more than one RAID controller with one power supply Install a PSPB with additional power supplies. Plug and Play or PCI resource configuration failure Reboot the system. If the problem persists, run the RCU to identify the resource conflict and then reallocate system resources accordingly. 3-10 Dell PowerEdge 4300 Systems Service Manual