Dell PowerEdge C4140 EMC Installation and Service Manual - Page 24

Processor specifications, Supported operating systems, PSU specifications, Cooling fans - power consumption

Page 24 highlights

Processor specifications The PowerEdge C4140 system supports two 2nd Generation Intel Xeon Scalable processors with up to 26 cores per processor. NOTE: Ensure that both the processors are populated and both are of same type or model. NOTE: Processor sockets are not hot-pluggable. Supported operating systems The Dell EMC PowerEdge C4140 supports the following operating systems: • Canonical Ubuntu LTS • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware ESXi NOTE: For more information on the specific versions and additions, go to www.dell.com/support/home/us/en/04/ Drivers/SupportedOS/poweredge-c4140 PSU specifications The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU): Table 8. PSU specifications PSU Class Heat dissipation (maximum) Frequency 2400 W AC Titanium 9000 BTU/hr 50/60 Hz 2000 W AC Platinum 7500 BTU/hr 50/60 Hz Voltage AC High line 100-240 V 100-240 V AC, 2400 W autoranging 100-240 V AC, 2000 W autoranging Current Low line 100- 120 V NA 16 A NA 11.5 A NOTE: • Heat dissipation is calculated using the PSU wattage rating. • This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V. Cooling fans specifications The Dell EMC PowerEdge C4140 system supports up to eight standard cooling fans. NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. Table 9. Dell EMC PowerEdge C4140 fan support matrix Processor count Fan 1 Fan 2 Fan 3 Fan 4 2 Required Required Required Required Fan 5 Required Fan 6 Required Fan 7 Required Fan 8 Required NOTE: Each fan is listed in the systems management software, referenced by the respective fan number. If there is a problem with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the cooling fan assembly. 24 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Processor specifications
The PowerEdge C4140 system supports two 2nd Generation Intel Xeon Scalable processors with up to 26 cores per processor.
NOTE:
Ensure that both the processors are populated and both are of same type or model.
NOTE:
Processor sockets are not hot-pluggable.
Supported operating systems
The Dell EMC PowerEdge C4140 supports the following operating systems:
Canonical Ubuntu LTS
Microsoft Windows Server
Red Hat Enterprise Linux
SUSE Linux Enterprise Server
VMware ESXi
NOTE:
For more information on the specific versions and additions, go to
www.dell.com/support/home/us/en/04/
Drivers/SupportedOS/poweredge-c4140
PSU specifications
The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU):
Table 8. PSU specifications
PSU
Class
Heat
dissipation
(maximum)
Frequency
Voltage
AC
Current
High line
100–240 V
Low line 100–
120 V
2400 W AC
Titanium
9000 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
2400 W
NA
16 A
2000 W AC
Platinum
7500 BTU/hr
50/60 Hz
100–240 V AC,
autoranging
2000 W
NA
11.5 A
NOTE:
Heat dissipation is calculated using the PSU wattage rating.
This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
Cooling fans specifications
The Dell EMC PowerEdge C4140 system supports up to eight standard cooling fans.
NOTE:
When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Table 9. Dell EMC PowerEdge C4140 fan support matrix
Processor
count
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
Fan 7
Fan 8
2
Required
Required
Required
Required
Required
Required
Required
Required
NOTE:
Each fan is listed in the systems management software, referenced by the respective fan number. If there is a
problem with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the
cooling fan assembly.
24
Technical specifications