Dell PowerEdge C4140 EMC Installation and Service Manual - Page 80

Expansion cards and expansion card risers, Expansion card installation guidelines

Page 80 highlights

Figure 44. Installing a memory module Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system on page 58. 3. To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System BIOS > Memory Settings. In the Memory Settings screen, the System Memory Size must reflect the updated capacity of the installed memory. 4. If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is firmly seated in the memory module socket. 5. Run the system memory test in system diagnostics. Expansion cards and expansion card risers NOTE: A System Event Log (SEL) event is logged if an expansion card riser is not supported or missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/ poweredgemanuals. Expansion card installation guidelines Depending on your system configuration, the following PCI Express (PCIe) generation 3 expansion cards are supported: Table 36. Expansion card riser configurations Expansion card riser PCIe slots on the riser Riser 1A Riser 2A Slot 1 Slot 2 Slot 3 Processor connection Processor 1 Processor 1 Processor 2 Height Low Profile Low Profile Low Profile Length Half Length Half Length Half Length Slot width x16 x4 x16 NOTE: The expansion card slots are not hot-swappable. The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order. 80 PowerEdge C4140 installing and removing system components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Figure 44. Installing a memory module
Next steps
1.
Install the air shroud
.
2.
Follow the procedure listed in
After working inside your system
on page 58.
3.
To verify if the memory module has been installed properly, press F2 and navigate to
System Setup Main Menu > System BIOS >
Memory Settings
. In the
Memory Settings
screen, the System Memory Size must reflect the updated capacity of the installed
memory.
4.
If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is firmly
seated in the memory module socket.
5.
Run the system memory test in system diagnostics.
Expansion cards and expansion card risers
NOTE:
A System Event Log (SEL) event is logged if an expansion card riser is not supported or missing. It does not
prevent your system from turning on. However, if a F1/F2 pause occurs with an error message, see
Troubleshooting
expansion cards
section in the
Dell EMC PowerEdge Servers Troubleshooting Guide
at
www.dell.com/
poweredgemanuals
.
Expansion card installation guidelines
Depending on your system configuration, the following PCI Express (PCIe) generation 3 expansion cards are supported:
Table 36. Expansion card riser configurations
Expansion card riser
PCIe slots on the riser
Processor
connection
Height
Length
Slot
width
Riser 1A
Slot 1
Processor 1
Low Profile
Half Length
x16
Slot 2
Processor 1
Low Profile
Half Length
x4
Riser 2A
Slot 3
Processor 2
Low Profile
Half Length
x16
NOTE:
The expansion card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with
the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card
priority and slot priority order.
80
PowerEdge C4140 installing and removing system components