Dell PowerVault LTO4-120HH Dell DR Series System Administrator's Guide - Page 153

Description/Meaning or Action, Storage Controller &lt

Page 153 highlights

Alert Message Temperature probes have recorded temperatures in the failed range. Description/Meaning or Action • Check the Events page in the DR Series system for specific temperature events and the location of the temperature probes. • Check the data center air conditioning, ventilation, and internal system cooling fans for any problems. • Ensure there is proper air flow through the storage appliance, and as needed, clean the cooling vents. Voltage probes have recorded readings in the failed range. • Check the Events page in the DR Series system for specific voltage events and the location of the voltage probes. • Check the power supplies. If there are no issues with the power supplies, have a service technician check the DR Series system appliance to see if it requires any servicing. Storage Controller failed. Replace the RAID controller in the DR Series system. Storage Controller is missing. Reinsert or replace the RAID controller in the DR Series system. Storage Controller has an illegal configuration. The expected number of virtual drives is , and the actual number of virtual drives found was . Run the Dell Restore Manager (RM) utility to repair the drive configuration mismatch. The expected number of enclosures is , and the actual number of enclosures found was . • Check the SAS cable connections between the storage controller and all its enclosures. • Check the power cable connections to the enclosure power supplies. Physical disk failed. Physical disk is missing, removed, or it cannot be detected. Physical disk predictive failure reported. Replace the physical disk that failed. Reinsert or replace the physical disk. Replace the physical disk. NOTE: Even though the disk may not have failed yet, the recommended best practice is to replace the disk. Physical disk is an unsupported type. Physical disk has been manually set to offline with a configuration command. Physical disk is foreign. This disk type is unsupported and cannot be used in this configuration. Replace the unsupported physical disk with a Dellsupported SAS physical disk. Remove the physical disk and reinsert it (the drive is nonoperational in this state). This can occur when a storage controller has been replaced or all drives have been migrated from another system. In such cases, the foreign configuration should be imported. 153

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176

Alert Message
Description/Meaning or Action
Temperature probes have recorded temperatures in the
failed range.
Check the
Events
page in the DR Series system for
specific temperature events and the location of the
temperature probes.
Check the data center air conditioning, ventilation,
and internal system cooling fans for any problems.
Ensure there is proper air flow through the storage
appliance, and as needed, clean the cooling vents.
Voltage probes have recorded readings in the failed
range.
Check the
Events
page in the DR Series system for
specific voltage events and the location of the
voltage probes.
Check the power supplies. If there are no issues
with the power supplies, have a service technician
check the DR Series system appliance to see if it
requires any servicing.
Storage Controller <
number
> failed.
Replace the RAID controller in the DR Series system.
Storage Controller <
number
> is missing.
Reinsert or replace the RAID controller in the DR Series
system.
Storage Controller <
number
> has an illegal configuration.
The expected number of virtual drives is <
number
>, and
the actual number of virtual drives found was <
number
>.
Run the Dell Restore Manager (RM) utility to repair the
drive configuration mismatch.
The expected number of enclosures is <
number
>, and the
actual number of enclosures found was <
number
>.
Check the SAS cable connections between the
storage controller and all its enclosures.
Check the power cable connections to the
enclosure power supplies.
Physical disk <
number
> failed.
Replace the physical disk that failed.
Physical disk <
number
> is missing, removed, or it cannot
be detected.
Reinsert or replace the physical disk.
Physical disk <
number
> predictive failure reported.
Replace the physical disk.
NOTE:
Even though the disk may not have failed yet,
the recommended best practice is to replace the disk.
Physical disk <
number
> is an unsupported type.
This disk type is unsupported and cannot be used in this
configuration.
Replace the unsupported physical disk with a Dell-
supported SAS physical disk.
Physical disk <
number
> has been manually set to offline
with a configuration command.
Remove the physical disk and reinsert it (the drive is non-
operational in this state).
Physical disk <
number
> is foreign.
This can occur when a storage controller has been
replaced or all drives have been migrated from another
system. In such cases, the foreign configuration should be
imported.
153