Epson R200 Service Manual - Page 17
Occurrence Timing, Position of CR, Phenomenon Detail, Faulty Part, Part Name, Check Point, Remedy - stylus photo ink levels
UPC - 010343849532
View all Epson R200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
EPSON Stylus Photo R200/R210 Revision A Table 1-6. Check Points for Paper Out Error to Each Phenomenon Occurrence Timing Position of CR Phenomenon Detail Faulty Part/ Part Name Check Point Remedy 1. Check if "Compression Spring, 2.36" of "Lever, Change" 1. Replace "Ink System" with a new one. does not come off. "PF Motor" and "Spur Gear, 37.242" rotate properly, but "Holder, Shaft, LD Roller" does not feed paper. (The drive of "PF Motor" does not propagate to "Holder, Shaft, LD Roller".) Ink System Lever, Change At operation - At operation - "Holder, Shaft, LD Roller" is not set in the ASF home position and paper is always fed from "ASF Assy.". "Holder, Shaft, LD Roller" does not feed paper during the feeding operation. "PF Motor" and "Spur Gear, 37.242" also does not rotate at all. "Holder, Shaft, LD Roller" rotates properly, but paper is not fed. Ink System Compression Spring, 2.36 1. Check if the tip of "Lever, Change" is not damaged. 1. Replace "Ink System" with a new one. PF Motor* Holder, Shaft LD Roller 1. Check if "PF Connector Cable" is connected to CN6 on "Main Board". 2. Check if the coil resistance of "PF Motor" is approximately 3.0W with a tester. Refer to Table 1-1. 3. Check if "PF Motor Connector Cable" is damaged. 1. Connect "PF Motor Connector Cable" to CN6 on "Main Board". 2. Replace "PF Motor" with a new one. 3. Replace "PF Motor" with a new one. 1. Check if the surface of "LD Roller" is contaminated with 1. Remove the dust by using a soft bruch or soft paper dust. cloth moistened with alcohol. * If the problem is not solved, replace "LD Roller" with a new one. LD Roller TROUBLESHOOTING Unit Level Troubleshooting 17