EPSON Stylus Photo R200/R210 Revision A Table 1-10. Check Points for Fatal Error to Each Phenomenon Occurrence Timing Position of CR Phenomenon Detail Faulty Part/ Part Name Check Point Remedy "CR Motor" does not work at all when turning on the power. "Carriage Unit" strikes on "Lever, Change" which is leaning forward when turning on the power. CR Motor PF Motor 1. Check if "CR Motor Connector Cable" is connected to CN5 on "Main Board". 2. Check if "CR Motor Connector Cable" is not damaged. 1. Connect "CR Motor Connector Cable" to CN5 on "Main Board". 2. Replace "CR Motor" with a new one. 1. Check if "PF Motor Connector Cable" is connected to CN6 on "Main Board". 2. Check if the resistance of "PF Motor" is approximately 3.0W using a tester. Refer to Table 1-1. 3. Check if "PF Motor Connector Cable" is not damaged. 1. Connect "PF Motor Connector Cable" to CN6 on "Main Board". 2. Replace "PF Motor" with a new one. 3. Replace "PF Motor" with a new one. 1. Check if "Compression Spring, 2.36" of "Lever, Change" 1. Replace "Ink System" with a new one. has not come off. Lever, Change At power-on Out of HP Ink System Compression Spring, 2.36 1. Check if "Paper Guide, Upper" has not come off from "Main Frame". 1. Reassemble "Paper Guide, Upper" to "Main Frame". "Carriage Unit" strikes on "Paper Guide, Upper" which has come off from "Main Frame" when turning on the power. Paper Guide, Upper Paper Guide, Upper At power-on Anywhere "Carriage Unit" strikes on the right side of "Main Frame" when turning on the power. CR Scale 1. Check if "CR Scale" has not come off or it properly passes through the slit of "CR Encoder Sensor Board". 1. Reassemble "CR Scale" correctly. * If the problem is not solved, replace "Main Board" with a new one. TROUBLESHOOTING Unit Level Troubleshooting 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

EPSON Stylus Photo R200/R210
Revision A
TROUBLESHOOTING
Unit Level Troubleshooting
23
Table 1-10.
Check Points for Fatal Error to Each Phenomenon
Occurrence Timing
Position of CR
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
At power-on
Out of HP
"CR Motor" does not work at all when
turning on the power.
CR Motor
1.
Check if "CR Motor Connector Cable" is connected to
CN5 on "Main Board".
2.
Check if "CR Motor Connector Cable" is not damaged.
1.
Connect "CR Motor Connector Cable" to
CN5 on "Main Board".
2.
Replace "CR Motor" with a new one.
"Carriage Unit" strikes on "Lever,
Change" which is leaning forward when
turning on the power.
PF Motor
1.
Check if "PF Motor Connector Cable" is connected to
CN6 on "Main Board".
2.
Check if the resistance of "PF Motor" is approximately
3.0
±
using a tester. Refer to Table 1-1.
3.
Check if "PF Motor Connector Cable" is not damaged.
1.
Connect "PF Motor Connector Cable" to CN6
on "Main Board".
2.
Replace "PF Motor" with a new one.
3.
Replace "PF Motor" with a new one.
Ink System
1.
Check if "Compression Spring, 2.36" of "Lever, Change"
has not come off.
1.
Replace "Ink System" with a new one.
"Carriage Unit" strikes on "Paper Guide,
Upper" which has come off from "Main
Frame" when turning on the power.
Paper Guide,
Upper
1.
Check if "Paper Guide, Upper" has not come off from
"Main Frame".
1.
Reassemble "Paper Guide, Upper" to "Main
Frame".
At power-on
Anywhere
"Carriage Unit" strikes on the right side
of "Main Frame" when turning on the
power.
CR Scale
1.
Check if "CR Scale" has not come off or it properly
passes through the slit of "CR Encoder Sensor Board".
1.
Reassemble "CR Scale" correctly.
*
If the problem is not solved, replace
"Main Board" with a new one.
Lever, Change
Compression Spring, 2.36
Paper Guide, Upper