Epson R200 Service Manual - Page 65
When reinstalling Lever, Lock, Slider
![]() |
UPC - 010343849532
View all Epson R200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
EPSON Stylus Photo R200/R210 o External View (Cont.) Frame, Cap Slider, Cap Extension Spring, 0.788 Lever, Lock, Slider Extension Spring, 0.441 Hooks Porous Pad, Slider, Cap Hook Shaft Figure 2-42. "Ink System Unit" removal (2) Revision A 9. Remove "Extension Spring, 0.441" from the hooks of "Slider, Cap" and "Frame, Cap" by using the tweezers. 10. Remove "Extension Spring, 0.788" from the hooks of "Lever, Lock, Slider" and "Frame, Cap" by using the tweezers. 11. Remove the shaft of "Slider, Cap" from the slot of "Frame, Cap", then remove "Lever, Lock, Slider". 12. Remove "Porous, Slider, Cap" from the hook of "Slider, Cap". o When reinstalling "Lever, Lock, Slider", n Check if it works properly working with "Slider, Cap". o When reinstalling "Ink System", n Make sure that the ink tube is correctly connected to the point of "Frame, Cap" shown in the figure below. If it is not connected properly, it may cause ink leakage. Figure 2-43. Connecting Point for the ink tube n Do not touch the sealing rubber part and "Cleaner Head". n Make sure that the line mark of the ink tube is not twisted. n Check if "Cap Assy." moves smoothly. DISASSEMBLY AND ASSEMBLY Disassembly 65
![](/manual_guide/products/epson-r200-service-manual-1506266/65.png)