Epson R200 Service Manual - Page 42
Offset Input for CR Motor Calorific Limitation When
![]() |
UPC - 010343849532
View all Epson R200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
EPSON Stylus Photo R200/R210 2.3.4 CR Motor removal o External View Backside Hook CR Motor Revision A o Disassembly Procedure 1. Disconnect the CR motor connector cable from the connector (CN5) of "Board, Main". 2. Release the CR motor connector cable from the "Holder, Shaft Unit". 3. Release the carriage lock with the tweezers or alike, then move "Carriage Unit" to the centre of the printer. 4. Push "Pulley, Driven" in the direction of the arrow and loosen the tension of "Timing Belt". Then, remove "Timing Belt" from the pinion gear of "CR CN5 Motor". 5. Remove the screws (x2) which secure "CR Motor", and remove "CR Motor". C A U T I O N Do not damage the pinion gear when removing "CR Motor". Puller, Driven C.C 3x4 (3.5-4.5kgf•cm) 1 2 Timing Belt CR Motor Figure 2-8. CR Motor removal o Parts/Units which should be removed before removing "CR Motor" Paper Support Assy./Housing (left/right)/Housing (frame) o When reinstalling the "CR Motor", n Make sure to screw "CR Motor" in the order as shown in the figure. n Make sure that there is no gap between "CR Motor" and "Frame, Main". n Make sure that the part on which "CR Motor" Lot number is printed is face-up. A D JU S TM E N T R E Q U IR E D o When having removed or replaced "CR Motor", implement the adjustment in the following order. (Refer to Chapter 3 "ADJUSTMENT") 1. First dot Adjustment 2. PW Sensor Adjustment 3. Head Angular Adjustment 4. Bi-D Adjustment 5. Offset Input for CR Motor Calorific Limitation (When Replaced) DISASSEMBLY AND ASSEMBLY Disassembly 42
![](/manual_guide/products/epson-r200-service-manual-1506266/42.png)