Epson R200 Service Manual - Page 84
EPSON Stylus Photo R200/R210, Revision A, ADJUSTMENT, Adjustment Except Adjustment Program
![]() |
UPC - 010343849532
View all Epson R200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
EPSON Stylus Photo R200/R210 Revision A 5. Move "Carriage Unit" to the left edge of the printer, then set the Thickness Gauge (1.15mm) on the left ribs (X3) of "Paper Guide, Front". Ribs Thickness Gauge 7. Remove the Thickness Gauge and move "Carriage Unit" to the right edge. Then, set the Thickness Gauge on the right ribs (X3) of "Paper Guide, Front". Ribs Thickness Gauge Figure 3-7. Setting Thickness Gauge 6. Implement PG Adjustment on the left according to the flowchart in the Figure 3-8. Start Move "Carriage Unit" to the right by using "Timing Belt". Note: Take down toward the printer front by 1 notch: PG gets narrower. Take up toward the printer back by 1 notch: PG gets wider. Does the Thickness Yes Gauge move? No Take down "Bushing, Parallel Adjust, Left" toward the printer front by 1 notch. Take up: PG gets wider Take up "Bushing, Parallel Adjust, Left" toward the printer back by 1 notch. Move "Carriage Unit" to the right by using "Timing Belt". Does the Thickness Yes Gauge move? No Take down: PG gets narrower Go to Step 7. Figure 3-8. PG Adjustment (Left Side) Figure 3-9. Setting Thickness Gauge 8. Implement PG Adjustment on the right according to the flowchart in the Figure 3-10. Start Move "Carriage Unit" to the left by using "Timing Belt". Note: Take down toward the printer front by 1 notch: PG gets narrower. Take up toward the printer back by 1 notch: PG gets wider. Yes Does the Thickness Gauge move? No Take down "Bushing, Parallel Adjust, Right" toward the printer front by 1 notch. Take down: PG gets narrower Take up: PG gets wider Take up "Bushing, Parallel Adjust, Right" toward the printer back by 1 notch. Move "Carriage Unit" to the left by using "Timing Belt". Does the Thickness Yes Gauge move? No Go to Step 9. Figure 3-10. PG Adjustment (Right Side) ADJUSTMENT Adjustment Except Adjustment Program 84
![](/manual_guide/products/epson-r200-service-manual-1506266/84.png)