Gateway 995 995 Series Server User Guide - Page 142
BMC core Hardware, BMC Firmware Code
![]() |
View all Gateway 995 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 142 highlights
Chapter 6: Troubleshooting Code 0B52: 0B53: 0B5F: 0B60: 0B61: 0B62: 0B6F: 0B70: 0B71: 0B74: 0B75: 0B7C: 0B80: 0B81: 0B82: Error message Failure description Processor 3 with error Failed Processor 3, error detected taken offline Processor 4 with error Failed Processor 4,n error detected taken offline Forced to use CPU with An error detected in the entire CPU error DIMM bank 1 has been Memory error, memory bank 1 failed disabled DIMM bank 2 has been Memory error, memory bank 2 failed disabled DIMM bank 3 has been Memory error, memory bank 3 failed disabled DIMM bank with error is An error detected in all the memory enabled The error occurred during temperature sensor reading Error while detecting a temperature failure System temperature out Temperature error detected of the range The error occurred during voltage sensor reading Error while detecting voltage System voltage out of the range System voltage error The error occurred during redundant power module confirmation The error occurred while retrieving the power information BMC Memory Test Failed BMC device (chip) failed BMC Firmware Code BMC device(chip) failed Area CRC check failed BMC core Hardware failure BMC device(chip) failed 136 www.gateway.com
![](/manual_guide/products/gateway-computers-995-995-series-server-user-guide-d203082/142.png)