HP 750c Service Manual - Page 130
the nearest HP Support Office. Note
View all HP 750c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Error Code Problem Description 010050 Defective Postscript SIMM. Corrective Actions D Check/replace the Postscript SIMM. 010060 Primer motor/sensor initialize failure. D If the primer stepper motor operates, then check the primer sensor connection and/or operation. If it does not operate, replace the: D Primer ' page 6Ć41. D Cable assembly ' page 6Ć47. D Main PCA ' page 6Ć9. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed. D Make sure that the primer sensor is correctly positioned. 010080 RSĆ232ĆC data overflow. D Data byte was not read before another was entered into the UART. Check the handshake settings in the software application configuration. D Replace the main PCA ' page 6Ć9. D If the problem remains, report the problem to the HP Response Center or the nearest HP Support Office. 020001 020002 Memory fragmentation error. D Turn Queing to OFF in the frontĆpanel. D Add more memory. D If the problem remains, report the problem to the HP Response Center or the nearest HP Support Office. Note conditions before the error occurred. Include system configuration in the report. 8-12 Troubleshooting C4705-90000