AlarmGenID=id AlarmSW=[Y|N] AlarmSWID=id AlarmID=id, AlarmSev=severity AlarmPWR=[Y|N]
View all HP Carrier-grade cc3300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Command Switches Description ALARM -S -A id -L severity This command sets or adds a Telco Alarm record to the Telco Alarm database. The generator id will always be 47h and the software originator id will be 0. Parameters: [-A id] - Alarm ID [-L severity] - Alarm Severity Level. Severities are CRT (critical), MJR (major) and MNR (minor). The BMC returns any one of the following response: New alarm added to BMC TAM alarm database. Request alarm matches existing BMC TAM alarm database record. Request alarm updated an existing BMC TAM alarm database record. BMC TAM alarm database is full. Request alarm record bumped because of lower priority. BMC TAM alarm database is full. Request alarm record bumped existing record. ALARM -Q {{-G id {-O id} {-A id}} | {-L severity} {-P} } This command queries Telco alarm records in the Telco alarm database based on the options entered by the user. Options: [-G id] - Query against the generator ID specified. [-O id] - Query against the software originator ID specified. [-A id] - Query against the alarm ID specified. [-L severity] - Query against the severity specified. Severities are CRT (critical), MJR (major) and MNR (minor). [-P] - Query only alarms that are related to power. The BMC returns the response string in the following format: AlarmGenID=id AlarmSW=[Y|N] AlarmSWID=id AlarmID=id AlarmSev=severity AlarmPWR=[Y|N] ALARM -C ({{-G id {-O id} {-A id}} | {-L severity}} | ALL) This command clears all Telco records in the Telco alarm database based on the options entered by the user. Options: [-G id] - Clears alarms that match the generator ID specified. [-O id] - Clears alarms that match the software originator ID specified. [-A id] - Clears alarms that match the alarm ID specified. [-L severity] - Clears alarms that match the severity specified. Severities are CRT (critical), MJR (major) and MNR (minor). ALL - Clears all alarm records. The BMC returns the response string in the following format: (id value represented in decimal) Alarm ID id cleared (Generator ID id) SYS HELP COMMAND Displays the syntax and usage information for the command specified. If a command is not specified the current IPMI revision, FW version numbers and all supported commands are displayed. a. Execution of graceful OS shutdown has restrictions listed below.