CLI Commands perf.errors Syntax errors portNumber Purpose This command displays port error counters for a single port. Parameters This command has one parameter: portNumber Specifies the port number. Valid values are: 0-15 for the Edge Switch 2/16 0-23 for the Edge Switch 2/24 0-31 for the Edge Switch 2/32 0-63 for the Director 2/64 0-127 and 132-144 for the Director 2/140 Command Example Root> perf errors 2 Output The port error counter data is displayed as a table that includes the following statistics. Port The port number. Prim Seq Err The number of state machine protocol errors detected by the port hardware. Disc Frms The number of received frames discarded due to a frame size of less than size words or to frames dropped because the BB credit was zero. This number is counted during the first round of frame verification and applies to both Class 2 and Class 3 traffic. CLI reference guide for directors and edge switches 2-95