HP StorageWorks 2/140 CLI reference guide for directors and edge switches - Page 151
Attached WWN, Beaconing, Reason, No Response from Attached Switch
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
CLI Commands Type The operational port type. If the configured port type is F_Port or E_Port, this value will match the configured type. If the configured type is G_Port, this value can be E_Port, F_Port, or G_Port, depending on what is connected to the port. On the Edge Switch 2/24, if the configured port type is Fx_Port, the operational port type can include FL_Port in addition to the values noted above for F_Port. If the configured port type is Gx_Port, then the operational port type can include FL_Port in addition to the values noted above for G_Port. Attached WWN The World Wide Name of the device or Switch attached to the port, if one is attached. Beaconing The beaconing state for the port (true or false). Reason An optional message number that indicates if the port has a segmented ISL or if a port binding violation has occurred, or if the part is inactive. The message description for this message number is provided at the bottom of the table. If the operational state is Segmented E_Port, only the following messages can be generated: • 00 Segment Not Defined • 01 Incompatible Operating Parameters • 02 Duplicate Domain ID(s) • 03 Incompatible Zoning Configurations • 04 Build Fabric Protocol Error • 05 No Principal Switch • 06 No Response from Attached Switch • 07 ELP Retransmission Failure Timeout CLI reference guide for directors and edge switches 2-121
![](/manual_guide/products/hewlettpackard-316095b21-cli-reference-guide-directors-edge-switches-4b9015e/151.png)