Output Example, Edge Switch 2/24.
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
CLI Commands Speed The Switch speed. (This parliamentary is not valid for the Edge Switch 2/24.) Rerouting Delay The rerouting delay that ensures that frames are delivered in order through the fabric to their destination. Values are Enabled or Disabled. Interop Mode Interoperability mode for the Switch. Insistent Domain Id When enabled, ensures that the embedded firmware cannot change a Switch's preferred domain ID. Domain RSCN When enabled, allows domain RSCNs to be sent to registered members of the fabric Output Example The output from the config.switch.show command displays as follows. BB Credit: 2 R_A_TOV: 20 E_D_TOV: 4 Preferred Domain Id: 1 Switch Priority: Principal Speed: 2 Gb/sec Rerouting Delay: Enabled Interop Mode: Open Fabric 1.0 Insistent Domain Id: Disabled Domain RSCN: Enabled CLI reference guide for directors and edge switches 2-57