The E_D_TOV is entered
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
Error Messages Message Error 14: Invalid Port Name Error 15: Invalid BB Credit Error 16: Invalid R_A_TOV Error 17: Invalid E_D_TOV Description The value entered for the port name is invalid. The value entered for the buffer-to-buffer credit is invalid. The value entered for the resource allocation time-out value is invalid. The value entered for the error detect time-out value is invalid. Action The port name for the individual port can contain 0-24 characters. Enter a name with 0-24 characters. If spaces are used, enclose the name in quotation marks. The buffer-to-buffer credit must be an integer in the range 1-60. Enter a value in the range 1-60 characters. A buffer-to-buffer credit is not used for ports configured for extended distance. The R_A_TOV is entered in tenths of a second and must be an integer in the range 10-1200 (1 second to 120 seconds). The R_A_TOV value must be larger than the E_D_TOV value. Check to be sure that all these conditions are met and re-submit. The E_D_TOV is entered in tenths of a second and must be an integer in the range 2-600 (0.2 second to 60 seconds). The E_D_TOV value must be smaller than the R_A_TOV value. Check to be sure that all these conditions are met and re-submit. CLI reference guide for directors and edge switches A-3