HP StorageWorks 2/140 CLI reference guide for directors and edge switches - Page 177

config.switch.speed on, be Set at Higher Data

Page 177 highlights

Error Messages Message Error 101: Command Not Supported on This Product Error 102: Switch Not Operational Error 115: Invalid Switch Speed Error 116: Switch Not Capable of 2 Gbps Error 117: Ports Cannot be Set at Higher Data Rate than Switch Speed Error 118: Invalid Port Speed Description This product does not support the specified command. The request cannot be completed because the Switch is not operational. The request cannot be completed because the Switch is not capable of operating at the configured speed. The request cannot be completed because the Switch is not capable of operating at 2.125 gigabits per second (Gbps). The request cannot be completed because the requested port speed is faster than the configured Switch speed. This request cannot be completed because the requested port speed is not recognized for this product. Action Information only message: this operation is not supported. Refer to the product service manual, and consult your service representative. Refer to the product service manual to determine the speed capabilities of the product. Refer to the product service manual to determine the speed capabilities of the product. The Switch speed should first be configured to accommodate changes in the configured port speed. The ports cannot operate at a faster rate than the Switch itself. Update the Switch speed and resubmit the request. For more information about setting speeds, see config.switch.speed on page 2-55 and config.port.speed on page 2-17. Port speeds may be set to 1 Gbps or 2 Gbps. Update the port speed and resubmit the request. CLI reference guide for directors and edge switches A-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

CLI reference guide for directors and edge switches
A–13
Error Messages
Error 101: Command
Not Supported on This
Product
This product does not
support the specified
command.
Information only
message: this operation
is not supported.
Error 102: Switch Not
Operational
The request cannot be
completed because the
Switch is not operational.
Refer to the product
service manual, and
consult your service
representative.
Error 115: Invalid
Switch Speed
The request cannot be
completed because the
Switch is not capable of
operating at the configured
speed.
Refer to the product
service manual to
determine the speed
capabilities of the
product.
Error 116: Switch Not
Capable of 2 Gbps
The request cannot be
completed because the
Switch is not capable of
operating at 2.125 gigabits
per second (Gbps).
Refer to the product
service manual to
determine the speed
capabilities of the
product.
Error 117: Ports Cannot
be Set at Higher Data
Rate than Switch
Speed
The request cannot be
completed because the
requested port speed is
faster than the configured
Switch speed.
The Switch speed should
first be configured to
accommodate changes
in the configured port
speed. The ports cannot
operate at a faster rate
than the Switch itself.
Update the Switch speed
and resubmit the
request. For more
information about setting
speeds, see
config.switch.speed on
page 2-55
and
config.port.speed on
page 2-17
.
Error 118: Invalid Port
Speed
This request cannot be
completed because the
requested port speed is not
recognized for this product.
Port speeds may be set
to 1 Gbps or 2 Gbps.
Update the port speed
and resubmit the
request.
Message
Description
Action