Page 171 highlights
Error Messages Message Error 41: Invalid Minute Error 42: Invalid Second Error 44: Max SNMP Communities Defined Error 45: Not Allowed While Switch Online Error 55: Invalid Zone Name Description The value of the minute entered for the new system time is invalid. The value of the second entered for the new system time is invalid. A new SNMP community cannot be defined before removing an existing community from the list. The entered command requires that the Director or Edge Switch be set offline. The value entered for the zone name is invalid. Action The format of the time parameter must be hh:mm:ss. The minute must contain an integer in the range 0-59. Enter a time, including minutes in the range 0-59. The format of the time parameter must be hh:mm:ss. The second must contain an integer in the range 0-59. Enter a time, including seconds in the range 0-59. A total of six communities may be defined for SNMP. Remove at least one of the current communities, and then define the new community. Set the Director or Edge Switch offline before reentering the command. The zone name must contain 1-64 characters. Valid characters are ABCDEFGHIJKLMNOP QRSTUVWXYZabcdefgh ijklmnopqrstuvwxyz0123 456789$-^_ (spaces are not permitted, and the first character must be alphabetical). Enter a zone name in the range of 1-64 characters, using the valid characters. CLI reference guide for directors and edge switches A-7