HP dx7200 HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition - Page 172

Run Computer Setup and diagnostic, Parity RAM failure.

Page 172 highlights

POST Error Messages POST Error Messages (Continued) Screen Message Network Server Mode Active and No Keyboard Attached Probable Cause Keyboard failure while Network Server Mode enabled. Parity Check 2 System will not boot without fan. Parity RAM failure. CPU fan not installed or disconnected in VSFF chassis. Recommended Action Reconnect keyboard with computer turned off. Check connector for bent or missing pins. Ensure that none of the keys are depressed. Replace keyboard. Run Computer Setup and diagnostic utilities. Open hood, press the power button, and see if the processor fan spins. If not spinning, make sure the fan cable is plugged into the system board. Ensure the heatsink is properly seated. If the heatsink is properly installed and the fan connected but does not spin, replace the heatsink-fan assembly. C-8 390812-001 Service Reference Guide, dx7200

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

C–8
390812-001
Service Reference Guide, dx7200
POST Error Messages
Network Server Mode
Active and No
Keyboard Attached
Keyboard failure while
Network Server Mode
enabled.
Reconnect keyboard with computer
turned off.
Check connector for bent or missing
pins.
Ensure that none of the keys are
depressed.
Replace keyboard.
Parity Check 2
Parity RAM failure.
Run Computer Setup and diagnostic
utilities.
System will not boot
without fan.
CPU fan not installed or
disconnected in VSFF
chassis.
Open hood, press the power button, and
see if the processor fan spins. If not
spinning, make sure the fan cable is
plugged into the system board. Ensure
the heatsink is properly seated.
If the heatsink is properly installed and
the fan connected but does not spin,
replace the heatsink-fan assembly.
POST Error Messages
(Continued)
Screen Message
Probable Cause
Recommended Action