Honeywell NX4S1 Installation Guide - Page 70
A.4.3, Reader Tamper Inputs, A.4.4, Door Egress Inputs
View all Honeywell NX4S1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
NetAXS™ Standalone Operation NetAXS™ Panel Defaults A.4.3 Reader Tamper Inputs The card readers have a Tamper signal wired to the NetAXS™ panel. This is a two-state input configured as a Normally Closed contact. The following are the default Reader Tamper Input to Panel Input associations: Tamper LED Tamper 1 Tamper 2 Tamper 3 Tamper 4 Reports as... Input 9 Input 10 Input 11 Input 12 A.4.4 Door Egress Inputs The panel has a Request-To-Exit (Egress) input for each door. The default condition is a two-state input configured as Normally Closed contact. When the egress input is active, the associated output relay will be active. The following are the default egress input associations: Egress input 1 2 3 4 Controls relay... 1 2 3 4 Panel input SP1 SP3 SP5 SP7 Reports as... Input 1 Input 3 Input 5 Input 7 60 www.honeywell.com