Konica Minolta HP PageWide XL 5000 MFP User Guide - Page 62
CAUTION, IMPORTANT, Printhead, Replace
View all Konica Minolta HP PageWide XL 5000 MFP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
CAUTION: Avoid touching pins, leads, and circuitry when handling printheads, because these elements are sensitive to electrostatic discharge. Such devices are called ESD-sensitive devices. See Glossary on page 132. Electrostatic discharges are one of the main hazards to electronics products. This type of damage can reduce the life expectancy of the device. IMPORTANT: Recalibrate the printer after any printhead replacement (see Calibrate print bar on page 106). Make sure you have the right paper for the calibration loaded before replacing the printhead. Use gloves when handling any component of the ink system. 1. Ensure that all ink cartridges are at least 25% full. 2. Start the printhead replacement from the front panel: press , then the Printhead tab, then Replace. 3. If you have a top stacker, open it. 4. Wait for the printbar to reach the replacement position. 5. Open the top cover with both hands by pressing the side buttons. 6. Open the printbar cover. 56 Chapter 3 Ink system ENWW