Panasonic VB42050 VB42050 User Guide - Page 82
Station Lockout Code Assignment
![]() |
View all Panasonic VB42050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Attendant Features Station Lockout Code Assignment Station Lockout Code Assignment (CPC-S and CPC-M) Description The Station Lockout feature allows users to dial a Station Lockout code to restrict their phone from being used for outside calls. Station Lockout codes can be assigned through the attendant phone. Operation To program a Station Lockout code: 1. Press the ON/OFF key. • The phone issues intercom dial tone. • The ON/OFF LED lights. 2. Press the CONF key. 3. Dial "#8." 4. Dial the extension number. 5. Enter the desired key code (four digits). 6. Press the HOLD key. "STORE XXXX" (where "XXXX" is the key code) appears on the display. 7. Press the ON/OFF key. The ON/OFF LED goes off. Considerations • A locked extension can be used for Intercom Calls. • Station Lockout key codes can also be set through system programming. Revised April 2000 DBS 824-3.0/3.2-700 2-17