DC-Bias, Output voltage check, justment, check transfer charger voltage.
![]() |
View all Sharp UX-4000M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
UX-4000MU FO-2950MU/C 2 DC bias output voltage adjustment Adjust VR2 so that the output voltage is -310V ±5V For measurement, use the high voltage tester (effective value me- ter). - DC-Bias Output voltage check + DRUM DC-Bias VR1 (MC output voltage adjustment volume) - BC-Bias Output voltage check + VR2 (DV bias output adjustment volume) 3 Transfer charger voltage check After MC output voltage adjustment and DC bias output voltage adjustment, check transfer charger voltage. Check that the output voltage is +3200V ~ +3700V. For measurement, use a high voltage tester (effective value meter). + Transfer charger Output voltage check - D7 D8 DRUM + Transfer changer Output voltage check - Note: For measurement, do not remove Printer PWB from the bottom plate. Fig.3 VR1 (MC output voltage adjustment volume) 2 - 2 Fig.4 manuals4you.com
![](/manual_guide/products/sharp-ux4000m-service-manual-b4f9605/18.png)