Sharp UX-4000M Service Manual - Page 69
Panel Unit, Panel cable, Motor cable, CIS cable, Wire treatment
View all Sharp UX-4000M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
5 Remove two screws. 6 Pull DV bias electrode toward you, and remove it from the lower frame. UX-4000MU FO-2950MU/C Optical section • Do not touch the mirror fixing screw in the optical section. If touched, the mirror bracket may be change, causing a shift in the print image position or vague images. The mirror angle cannot be adjusted in the market. • Do not touch the volume attached. If touched, normal images cannot be produced. This adjustment cannot be made in the market. DV bias electrode 6 5 Fig. 50 Note for assembly • When attaching DV bias electrode, adjust so that the contact is over the DC-BIAS electrode of the PWB unit. Terminal Fig. 51 Note Fusing section: • When fixing the cable of the temperature fuse and the thermistor, put it neat inside the projection of the frame. If not, paper jams may be resulted. 33. Wire treatment Fig. 53 Panel Unit CIS cable Fig. 52 Motor cable Fig. 54 Panel cable 3 - 26