Sony PDWF75 User Manual (PDW-F75 Professional Disc Recorder Operating Manual f - Page 104

HD VANC LINE [>> HD line], SETUP BANK OPERATION [Setup Bank]: Settings related

Page 104 highlights

METADATA [Metadata]: Metadata settings Description ESSENCE MARK [> EssnceMk] SDI OUT [>> SDI out]: Select whether to output essence marks in the VANC of HD/SDSDI output. *ON [>>> ON]: Output. OFF [>>> OFF]: Do not output. SD VANC LINE [>> SDI line]: When SDI OUT is set to "ON", select the line of SDSDI output in which to output essence marks. 12LINE [>>> 12 line] to 19LINE [>>> 19 line]: Select in the range line 12 to line 19. Factory default setting: *17LINE (line 17) HD VANC LINE [>> HD line]: When SDI OUT is set to "ON", select the line of HDSDI output in which to output essence marks. 9LINE [>>> 9 line] to 20LINE [>>> 20 line]: Select in the range line 9 to line 20. Factory default setting:*17LINE (line 17) HD VANC INPUT [> HD VANC IN]: Make settings related to recording of the VANC data contained in HDSDI input. LINE [>> Line]: Select the line whose VANC you want to record *OFF [>>> OFF]: Do not record VANC from any line. 9LINE [>>> 9 LINE] to 20LINE [>>> 20 line]: Select from the range line 1 to line 20. Note When this item is set to any setting other than OFF, VANC packet information is saved in the DATA ITEM section of MXF files. DID [>> DID]: Select the DID 00 [>>> 00] to FF [>>> FF] of the VANC you want to Factory default setting: *00 [>>> 00] record. SDID [>> SDID]: Select the SDID in the VANC you want to record 00 [>>> 00] to FF [>>> FF] Factory default setting: *00 [>>> 00] DATA ITEM OUT [> DATA ITEM]: Specify whether to include OFF [>> OFF]: Do not include VANC packet information in the information from recorded VANC packets in data items data items. in the DATA ITEM section of MXF files. *ON [>> ON]: Include VANC packet information in data items. Note Set this menu item to OFF when you connect a nonlinear editing system that does not support DATA ITEM. SETUP BANK OPERATION [Setup Bank]: Settings related Description to menu bank operations Menu bank: This unit allows three different complete sets of menu settings to be saved in what are termed "menu banks" numbered 1 to 3. RECALL BANK 1 [> Recall 1]: Recall menu settings from menu bank 1. RECALL BANK 2 [> Recall 2] :Recall menu settings from menu bank 2 RECALL BANK 3 [> Recall 3]: Recall menu settings from menu bank 3. Operate with the following procedure. (1) Select the bank you want to recall, then press the ,/OUT button. Message "RECALL OK?" appears. (2) To recall, press the SET button. To quit recalling, press the RESET button. (3) To save the recalled bank, press the SET button once again. SAVE BANK 1 [> Save 1]: Save current menu settings to menu bank 1. SAVE BANK 2 [> Save 2]: Save current menu settings to menu bank 2. SAVE BANK 3 [> Save 3]: Save current menu settings to menu bank 3. Operate with the following procedure. (1) Select the bank you want to save, then press the ,/OUT button. Message "SAVE OK?" appears. (2) To save, press the SET button. To quit saving, press the RESET button. Chapter 6 Menus 104 System Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

104
System Menu
Chapter 6
Menus
ESSENCE MARK [>
EssnceMk]
SDI OUT [>> SDI out]:
Select
whether to output
essence marks in the
VANC of HD/SDSDI
output.
*
ON [>>> ON]:
Output.
OFF [>>> OFF]:
Do not output.
SD VANC LINE [>> SDI
line]:
When SDI OUT is
set to “ON”, select the
line of SDSDI output in
which to output essence
marks.
12LINE [>>> 12 line] to 19LINE [>>> 19 line]:
Select in the
range line 12 to line 19.
Factory default setting:
*
17LINE (line 17)
HD VANC LINE [>> HD line]:
When SDI OUT is set to
“ON”, select the line of
HDSDI output in which to
output essence marks.
9LINE [>>> 9 line] to 20LINE [>>> 20 line]:
Select in the
range line 9 to line 20.
Factory default setting:
*
17LINE (line 17)
HD VANC INPUT [> HD
VANC IN]:
Make settings
related to recording of the
VANC data contained in
HDSDI input.
LINE [>> Line]:
Select the
line whose VANC you
want to record
*
OFF [>>> OFF]:
Do not record VANC from any line.
9LINE [>>> 9 LINE] to 20LINE [>>> 20 line]:
Select from the
range line 1 to line 20.
Note
When this item is set to any setting other than OFF, VANC
packet information is saved in the DATA ITEM section of MXF
files.
DID [>> DID]:
Select the DID
of the VANC you want to
record.
00 [>>> 00] to FF [>>> FF]
Factory default setting:
*
00 [>>> 00]
SDID [>> SDID]:
Select the
SDID in the VANC you
want to record
00 [>>> 00] to FF [>>> FF]
Factory default setting:
*
00 [>>> 00]
DATA ITEM OUT [> DATA ITEM]:
Specify whether to include
the information from recorded VANC packets in data items
in the DATA ITEM section of MXF files.
OFF [>> OFF]:
Do not include VANC packet information in
data items.
*
ON [>> ON]:
Include VANC packet information in data items.
Note
Set this menu item to OFF when you connect a nonlinear
editing system that does not support DATA ITEM.
SETUP BANK OPERATION [Setup Bank]: Settings related
to menu bank operations
Description
Menu bank:
This unit allows three different complete sets of menu settings to be saved in what are termed “menu banks”
numbered 1 to 3.
RECALL BANK 1 [> Recall 1]:
Recall menu settings from
menu bank 1.
Operate with the following procedure.
(1)
Select the bank you want to recall, then press the
,
/OUT
button.
Message “RECALL OK?” appears.
(2) To recall, press the SET button.
To quit recalling, press the RESET button.
(3) To save the recalled bank, press the SET button once
again.
RECALL BANK 2 [> Recall 2] :
Recall menu settings from
menu bank 2
RECALL BANK 3 [> Recall 3]:
Recall menu settings from
menu bank 3.
SAVE BANK 1 [> Save 1]:
Save current menu settings to
menu bank 1.
Operate with the following procedure.
(1)
Select the bank you want to save, then press the
,
/OUT
button.
Message “SAVE OK?” appears.
(2)
To save, press the SET button.
To quit saving, press the RESET button.
SAVE BANK 2 [> Save 2]:
Save current menu settings to
menu bank 2.
SAVE BANK 3 [> Save 3]:
Save current menu settings to
menu bank 3.
METADATA [Metadata]: Metadata settings
Description