Sony PDWF75 User Manual (PDW-F75 Professional Disc Recorder Operating Manual f - Page 27

Preparations, Setting the System Frequency, Setting the System, Frequency

Page 27 highlights

Chapter 2 Preparations Preparations 2 Chapter Setting the System Frequency This unit is shipped with the system frequency still unset. Therefore, you need to set the system frequency before using the unit. (The unit cannot be used unless the system frequency is set.) Once it is set, the system frequency is retained even when the unit is powered off. To set the system frequency Use the following procedure. Rear panel POWER POWER 1 switch 2 ACCESS NETWORK LOCAL REMOTE LEVEL PHONES 0 0 -12 -12 -20 -20 -30 -30 -40 -40 -60 1 2 -60 3 4 4CH 16 BIT 3+4 MPEG HD SP 1080 60I VITC COOO1 REM:077M 00: 00 .00: 00 TCG EXT TC MODE PRESET RUN MODE REC RUN TC/VITC VITC DF/NDF NDF P2 CH 1 CH 2 CH 3 CH 4 F1 F2 F3 F4 CHAPTER MENU MARK1 F5 EXPAND PAGE DISPLAY SUB THUMB IN CLIP NAIL SET RESET VARIABLE REC PRESET PB KEY INHI CLIP ESSENCE MENU MARK PREV PLAY NEXT MARK2 STOP SHIFT TOP F REV F FWD END STANDBY OUT REC VAR JOG SHUTTLE EJECT 4 3 Time data display section 1 Power the unit on. "SYSTEM SEL" appears in the time data display section. SYSTEM SEL SYSTEM FREQ: 60I 50I 30P 25P 23.98P SELECT : ( )( )KEY DATA SET : SET KEY 2 Press the M/MARK1 button or the m/MARK2 button to select the system frequency to use. 3 Press the SET button. "NOW SAVING..." appears in the time data display section, and the modified setting is saved in the unit's memory. "COMPLETE ! !" appears when save processing finishes. If you have selected 60I, 30P, or 23.98P When you press the SET button with 60I, 30P, or 23.98P selected in step 2, the following screen appears. SYSTEM SEL SYSTEM FREQ : 601 UC/J SELECT : UC UCP J SELECT : ( )( )KEY DATA SET : SET KEY Press the M/MARK1 and m/MARK2 buttons to select "UC" (for areas outside Japan) or "J" (for Japan), then press the SET button. 27 Setting the System Frequency

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

27
Setting the System Frequency
Chapter
Chapter 2
Preparations
2
Preparations
Setting the System
Frequency
This unit is shipped with the system frequency still unset.
Therefore, you need to set the system frequency before
using the unit. (The unit cannot be used unless the system
frequency is set.)
Once it is set, the system frequency is retained even when
the unit is powered off.
To set the system frequency
Use the following procedure.
1
Power the unit on.
“SYSTEM SEL” appears in the time data display
section.
2
Press the
M
/MARK1 button or the
m
/MARK2 button
to select the system frequency to use.
3
Press the SET button.
“NOW SAVING...” appears in the time data display
section, and the modified setting is saved in the unit’s
memory.
“COMPLETE ! !” appears when save processing
finishes.
If you have selected 60I, 30P, or 23.98P
When you press the SET button with 60I, 30P, or
23.98P selected in step
2
, the following screen
appears.
Press the
M
/MARK1 and
m
/MARK2 buttons to select
“UC” (for areas outside Japan) or “J” (for Japan), then
press the SET button.
PHONES
VAR
JOG
MARK1
MENU
PAGE DISPLAY
SUB
CLIP
F1
F5
F4
F3
F2
SHIFT
CLIP
MENU
ESSENCE
MARK
SET
THUMB
NAIL
RESET
OUT
IN
MARK2
SHUTTLE
TOP
KEY INHI
EXPAND
CHAPTER
F REV
F FWD
END
PREV
NEXT
PLAY
STOP
STANDBY
REC
EJECT
CH 1
CH 2
CH 3
CH 4
NETWORK
LOCAL
REMOTE
ACCESS
LEVEL
REC
VARIABLE
PRESET
PB
-12
0
-30
-20
1
-40
-12
0
-30
-20
-60
3
-40
4
2
4CH
MPEG HD
SP
VITC
REM:077
M
COOO1
1080
60I
16 BIT
3+4
00:00.00:00
DF/NDF
NDF
P2
TC/VITC
VITC
TC
MODE
PRESET
TCG
EXT
RUN MODE
REC
RUN
1
3
4
2
POWER
Time data display section
Rear panel
POWER
switch
SYSTEM SEL
SYSTEM FREQ:
60I
50I
30P
25P
23.98P
SELECT : ( )( )KEY
DATA SET :
SET KEY
SYSTEM SEL
SYSTEM FREQ : 601
UC/J SELECT :
UC
UC
P
J
SELECT : ( )( )KEY
DATA SET :
SET KEY