Cisco CSS 11501 Getting Started Guide - Page 135
Offline DM Verification of the Boot Configuration Record and Disk, Reseat the SCM.
UPC - 746320761664
View all Cisco CSS 11501 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
Appendix A Troubleshooting the Boot Process Diagnostic Tests for Hardware and Error Messages Table A-1 Fields in the Diagnostic Monitor Error Message (continued) Field Test_name Failure_details Description Provides the name of the test reporting the error. For example: Uart Interrupt Test PHY Reset Test Provides information about the error. For example: PHY Reset Register failed to clear. Addr: 0x12345678 Expected: 0x0 Actual:0xf After the CSS performs the diagnostics, it boots the Offline DM as indicated by the following message: Booting OffDm @ 0xbfd70000 See the "Offline DM Verification of the Boot Configuration Record and Disk" section for the Offline DM verification of the boot configuration record and disk drive. If the Booting OffDm message does not appear, a CSS 11501 component failure or an SCM failure may have occurred; such a failure would not allow a software download to start. If this problem occurs for a CSS 11501, contact Cisco Technical Assistance Center (TAC) for technical assistance. If this problem occurs for a CSS 11503 or CSS 11506: 1. Power down the CSS. 2. Reseat the SCM. 3. Power up the CSS. If reseating the module does not correct the failure, contact TAC for technical assistance. OL-6037-01 Cisco Content Services Switch Getting Started Guide A-5