- Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 1
ProLiant 8500 Servers Setup and Installation Guide First Edition (May 1999) Part Number 323333-001 Compaq Computer Corporation - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 2
. Pentium is a registered trademark and Xeon is a trademark of Intel Corporation. Other product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. Compaq ProLiant 8500 Servers Setup and Installation Guide First Edition (May 1999) Part Number - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 3
Introduction Compaq ProLiant 8500 Servers 1-1 Features ...1-3 Processor and Redundant Processor Power Modules 1-3 System Memory 1-4 Cache Controllers 1-5 Network Controller 1-6 Supported Interfaces 1-6 Video ...1-6 Service Improvement Features 1-6 Power Supplies 1-7 Remote-Flash Redundant - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 4
iv Compaq ProLiant 8500 Servers Setup and Installation Guide Introduction continued Major Hardware Options 1-9 Server Configuration and Management 1-10 Compaq SmartStart 1-10 Compaq System Configuration Utility 1-10 Windows NT Utilities 1-11 NetWare Utilities 1-11 Compaq Insight Manager 1-11 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 5
3-11 Chapter 4 Installing Hardware Options Installing a Hot-Plug Power Supply 4-2 Installing a Pentium III Xeon Processor and Processor Power Module 4-5 Installing the Cache Accelerator 4-11 SDRAM Memory 4-13 Adding or Replacing Memory 4-14 Mass Storage...4-17 SCSI Hard Drive Installation - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 6
vi Compaq ProLiant 8500 Servers Setup and Installation Guide Chapter 5 SCSI Setup Features...5-1 Installing the Integrated Array Bypass 5-3 Procedure ...5-3 Option ROM-Based Array Configuration Utility 5-6 Array Configuration Utility 5-7 Starting the Compaq Array Configuration Utility 5-8 On- - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 7
Guide vii Chapter 8 Initial Startup and Troubleshooting Powering on the Server Battery Replacement Notice A-7 Appendix B Electrostatic Discharge Grounding Methods B-2 Appendix C Power Cord Set Requirements General Requirements C-1 Country-Specific Requirements C-2 Appendix D Server Specifications - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 8
Guide can be used for step-by-step instructions for installation, and as a reference for operation, troubleshooting, and future upgrades for Compaq ProLiant 8500 Servers. WARNING: To reduce the risk of personal injury from electrical shock and hazardous energy levels, only authorized service - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 9
x Compaq ProLiant 8500 Servers Setup and Installation Guide Symbols in Text These symbols may be found in the text of this guide. They have the : Text set off in this manner presents clarifying information or specific instructions. NOTE: Text set off in this manner presents commentary, sidelights - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 10
heavy equipment handling. Power Supplies or Systems marked with these symbols indicate the equipment is supplied by multiple sources of power. WARNING: To reduce the risk of injury from electrical shock, remove all power cords to completely disconnect power from the system. Compaq Technician Notes - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 11
xii Compaq ProLiant 8500 Servers Setup and Installation Guide WARNING: To reduce the risk of electric shock or damage to the equipment: s If the system has multiple power supplies, disconnect power from the system by unplugging all power cords from the power supplies. s Do not disable the power cord - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 12
About This Guide xiii Telephone Numbers For the name of your nearest Compaq Authorized Reseller: s In the United States, call 1-800-345-1518 s In Canada, call 1-800-263-5868 s For Compaq technical support: s In the United States and Canada, call 1-800-386-2172 s For Compaq technical support phone - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 13
ProLiant 8500, the ultimate high-density data center server, delivers breakthrough 8-way scalable performance for 24x7 multi-server rack environments. The ProLiant 8500, which is based on the ProFusion 8-way architecture, delivers this performance through state-of-the-art Intel Pentium III Xeon - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 14
1-2 Compaq ProLiant 8500 Servers Setup and Installation Guide In Compaq ProLiant 8500 servers, you can access options and accessories easily through a sliding top access panel and three removable modules: the Processor and Memory module, the Media module, and the I/O Module. See Figures 2-1 and 2-2 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 15
Compaq ProLiant 8500 Server - rear view 1 I/O module with system fans 2 Integrated Server Lift Handles 3 Hot Plug Power Supplies Features The following features are available on Compaq ProLiant 8500 models: Processor and Redundant Processor Power Modules s Supports up to eight Pentium III Xeon - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 16
1-4 Compaq ProLiant 8500 Servers Setup and Installation Guide System Memory s ECC (Error Checking and Correcting Memory) with single-bit error correction and detection to a single DIMM, and multi-bit error detection to the memory bank s Supports 100 MHz Registered SDRAM s Expandable to 8 GB (16 GB - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 17
controller. Fixed Internal Media Drive Bays s Supports two non-hot-plug media drive bays: One third-height drive bay occupied by 1.44-MB diskette drive One third-height drive bay occupied by IDE CD-ROM drive Disk Controllers The Compaq ProLiant 8500 server is provided with an Dual Channel - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 18
1-6 Compaq ProLiant 8500 Servers Setup and Installation Guide Network Controller s Supports a dual-port 10/100 TX UTP controller on with 2 MB memory s From 16 to more than 256 colors, depending on graphics mode s Supports SVGA, VGA, and EGA graphics resolution Service Improvement Features s - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 19
. Refer to the table below to determine the number of power supplies needed for your server. Table 1-1 Power Supply Support Provided for System Configurations Power Supplies Power LineType Processors Hard Drives Memory PCI Expansion Cards 1 110 1 to 4 4 256MB to 4GB 3 to 5 1 220 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 20
1-8 Compaq ProLiant 8500 Servers Setup and Installation Guide System Power Management Guidelines Unless operating with two 1150W power supplies at 220V, it may be necessary to make tradeoffs with respect to which options can be added and powered with the installed power supplies. Use the following - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 21
instructions for the following server options: s Redundant hot-plug power supplies s Pentium III Xeon processors s Redundant processor power modules s Cache Accelerator s SDRAM memory s Hot-plug hard drives s I/O expansion boards (including PCI expansion boards with PCI Hot Plug driver support - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 22
1-10 Compaq ProLiant 8500 Servers Setup and Installation Guide Server Configuration and Management Compaq offers an extensive set of features and tools to support effective server configuration and management. Some are listed below: s Compaq SmartStart s Compaq System Configuration Utility s Compaq - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 23
Compaq servers running Windows NT take advantage of several utilities that provide detailed information and offer special capabilities. s Compaq Power Down Manager s Compaq Power Supply Viewer s Compaq Integrated Management Log Viewer The utilities are provided on the Compaq Support Software - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 24
1-12 Compaq ProLiant 8500 Servers Setup and Installation Guide Compaq Web-Based Management Compaq Web-Based Management allows you to access your managed Device List and the Compaq Insight Manager Alarm Log with a web browser, either locally at the management console or from another machine. If you - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 25
Introduction 1-13 Compaq Integrated Management Display The Integrated Management Display (IMD) is a server management tool delivering fault, service, and configuration capabilities in an easy-to-use, integrated hardware display. IMD features include: s POST (Power-On Self-Test) messages s User- - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 26
Some of the software, firmware, and hardware features of the Compaq ProLiant 8500 server that facilitate serviceability include: s Modular design s All diagnostic LEDs viewable from the exterior s Power-On Self-Test (POST) s Diagnostics (DIAGS) s ROMPaq utilities to upgrade flash ROMs s Array - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 27
ProLiant 8500 server to be mounted in a Compaq or industry-standard 19-inch rack, and to complete installation. Preparing the Server Installing the server the server. See the next sections, "Optimum Environment" and "Unpacking the Shipping Boxes" in this chapter. 2. Remove the power-supply and - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 28
2-2 Compaq ProLiant 8500 Servers Setup and Installation Guide 6. Remove the Processor and Memory module, Media Module, and power supplies to lighten the chassis. 7. Verify switch settings: bus/core frequency switches and system configuration switch. Refer to the Compaq ProLiant 8500 Hardware - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 29
should be a minimum of 30 inches to allow for servicing and for adequate airflow. Power Requirements WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 30
Compaq ProLiant 8500 Servers Setup and Installation Guide Grounding For proper operation and safety, this equipment is required to be properly grounded in accordance with ANSI/NFPA 70-1999, Article 250. All power the unit to an AC supply. When using power strips for electrical distribution, make - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 31
Table 2-1 Rack Internal Temperature Maximums Equipment Included Rack-Mountable ProLiant Servers Compaq Rack-Mountable options Other manufacturers' options Maximum Internal Rack Temperature 43°C/122°F 40°C/104°F See other manufacturers' specifications CAUTION: To reduce the risk of damage to the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 32
2-6 Compaq ProLiant 8500 Servers Setup and Installation Guide Airflow Requirements The Compaq ProLiant 8500 server draws cool air in through the front door and exhausts warm air out through the rear door. Therefore, the front door of the rack must - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 33
materials: s ProLiant 8500 Server - located inside shipping box s Power cord(s) - located inside country kit box s Documentation inside the server (Most of the option installation and setup instructions are located on hood labels on top of the unit and on the sides of the Processor and Memory module - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 34
2-8 Compaq ProLiant 8500 Servers Setup and Installation Guide Removing the Shipping Brackets and Screws To protect the power supply and I/O Module from any damage during shipment, each is installed with a protective covering bracket. Use the following illustration to loosen the screw and remove the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 35
Installation 2-9 2 1 Figure 2-2. Removing the I/O Shipping bracket The ProLiant 8500 server has a top latch security screw as shown in the following figure. The top latch security screw is provided to prevent access to the Processor and Memory module and the I/O module. If this screw is locked - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 36
2-10 Compaq ProLiant 8500 Servers Setup and Installation Guide Slide the top access panel open. Figure 2-4. Opening the top access panel Loosen the shipping screw between the Host Module and the I/O Module as shown in the following figure. 2 1 Figure 2-5. Loosening the shipping screw - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 37
the unit and on the sides of the Processor and Memory module. To access the appropriate label, see Chapter 4, "Installing Hardware Options." NOTE: These labels do not contain warning and caution information. Refer to this guide or to the option documentation for the applicable warnings and cautions - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 38
2-12 Compaq ProLiant 8500 Servers Setup and Installation Guide Rack Warnings and Precautions power supply before connecting the power cord to the power supply. s Unplug the power cord before removing the power supply from the server. s If the system has multiple power supplies, disconnect power - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 39
: Because the ProLiant 8500 server does not have safety interlocks, it is possible for a unit to be operated without the cover and air baffles properly installed. This could cause thermal damage in the system and may void your warranty. The Rack-Mountable Compaq ProLiant Server should always be - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 40
2-14 Compaq ProLiant 8500 Servers Setup and Installation Guide Attaching the Slide Rails to the Mounting Brackets The slide rails and mounting brackets form assemblies that attach to the rack. To attach the slide - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 41
Server Installation 2-15 3. Align the front screw holes in the slide rail and the mounting bracket. 4. Fasten the slide rail to the mounting bracket with three 8-32 x 1/4-inch slotted screws (supplied). 1 2 Figure 2-9. Attaching the slide rail to the mounting bracket 5. Repeat steps 1 through 4 for - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 42
2-16 Compaq ProLiant 8500 Servers Setup and Installation Guide Attaching the Slide Rail Assembly to the Rack Attaching the slide rail assembly to the rack consists of the following: s Marking the server's rack position with the template s Installing the slide rail assembly on the rack Marking the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 43
Server Installation 2-17 3. Remove the template from the rack by grasping the middle of the top and bottom edges and gently pulling the template as shown - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 44
2-18 Compaq ProLiant 8500 Servers Setup and Installation Guide Inserting Cage Nuts into the Rack Frame The cage nuts fit inside the rails at the marked locations. 1. Use the cage nut fitting tool to insert a cage nut into the rails. Squeeze the prongs together 1 and insert the cage nut into the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 45
Server Installation 2-19 Installing the Slide Rail Assembly to the Rack To install the slide rail assembly: 1. Place a mounting bracket in position according to the pencil - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 46
2-20 Compaq ProLiant 8500 Servers Setup and Installation Guide 3. power supplies and modules to reduce the weight of the chassis. s The unit will be unstable when not mated with the rails. IMPORTANT: To reduce the weight of the system, Compaq recommends that all power supplies, Processor and Memory - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 47
slides fully. Server Installation 2-21 Figure 2-15. Extending the slides 2. Remove the modules to lighten the chassis if desired (See Chapter 3, "Server Operation" for removal instructions.) 3. Lift the server with the recessed Integrated Server Lift Handles. 4. Set the server into the extended - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 48
2-22 Compaq ProLiant 8500 Servers Setup and Installation Guide Figure 2-16. Setting the server on the slide rails 5. Slide the server between the extended slides was removed for installation (power supplies, Processor and Memory Module, or Media Module). 8. Secure server to rack with thumbscrews. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 49
. Installing the Cable Management Arm Bracket The cable management arm bracket holds the cable management arm on the server. To install the cable management arm bracket: 1. Slide the server out or access it from the rear of the rack. 2. Attach the cable management arm bracket to the left side of - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 50
2-24 Compaq ProLiant 8500 Servers Setup and Installation Guide Installing the Cable Management Arm To attach the cable management arm: NOTE: The following procedure describes installing the Cable Management Arm supplied with the ProLiant 8500 server. For complex rack installations including a large - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 51
Server Installation 2-25 3. Align the other end of the cable management arm on the outside of the rear rack frame. Attach the end with the M6 x 1.0-12L washer face Phillips-head screws. Figure 2-19. Attaching the cable management arm to the rack - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 52
2-26 Compaq ProLiant 8500 Servers Setup and Installation Guide Cabling the Server 1. Connect the power cord(s) and peripheral devices such as the keyboard, mouse, and monitor. The following figure and table identifies the peripheral connectors on the back of the server. NOTE: When the power cord is - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 53
: s Install the power supply before connecting the power cord to the power supply. s Unplug the power cord before removing the power supply from the server. s If the system has multiple power supplies, disconnect power from the system by unplugging all power cords from the power supplies. s Do not - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 54
Compaq ProLiant 8500 Servers Setup and Installation Guide 4. Bundle all of the cables, including the power support and join the other cables in the opposite cable channel. 6. Extend the bundled cables down the rack's cable channel. Powering Up the Server You can now bring your ProLiant 8500 server - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 55
are the same as the current configurations, the system will boot normally. If you enter a wrong choice, on subsequent re-boots you may change your operating system selection. Powering Down the Server The system power in the ProLiant 8500 does not shut off completely with the front panel - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 56
below provides details concerning system power and power supply indicators and removal of the server modules. WARNING: The power supplies in the ProLiant 8500 server produce hazardous energy levels. The installation of options and the routine maintenance and service of this product should be - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 57
3-2 Compaq ProLiant 8500 Servers Setup and Installation Guide System Power The system power in the ProLiant 8500 Server does not shut off completely with the front panel Power On/Standby switch. The two modes of the power switch are ON and STANDBY, rather than ON and OFF. The STANDBY position - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 58
Server Operation 3-3 Power Supply Indicators Each power supply has status and AC power indicators. See Figure 3-1 and Table 3-1 for a detailed description of both indicators. 1 2 Figure 3-1. Power supply indicators Table 3-1 Power Supply Indicators Indicator 1 Status Condition Green Green/Amber - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 59
3-4 Compaq ProLiant 8500 Servers Setup and Installation Guide Numbering of Power Supplies The ProLiant 8500 server is provided with the capability for two hot-plug, redundant power supplies. See Chapter 4, "Installing Hardware Options," or the option documentation to replace a power supply. 2 1 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 60
controller has stopped responding, or the system has recorded a temperature violation. Note 2: A power supply has stopped providing adequate power as per system specifications, the system has experienced a short, a PPM has failed, or a reboot has been initiated via Automatic Server Recovery (ASR-2). - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 61
3-6 Compaq ProLiant 8500 Servers Setup and Installation Guide Server Access Panel and Modules The Compaq ProLiant 8500 server chassis facilitates the installation of hardware upgrades through the use of three removable modules and a sliding top access panel. The following table describes the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 62
in the following figure, and slide it toward the front of the server. Figure 3-4. Opening the top access panel 3. At this point, power is applied to the system. They are not hot pluggable. Immediate system shutdown and loss of data will occur. To replace or service non hot-plug components or problems - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 63
3-8 Compaq ProLiant 8500 Servers Setup and Installation Guide 2. Push in on the sides of the cam levers 1 on the I/O Module and rotate the top of the levers downward 2 as shown in the following - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 64
Module CAUTION: Do not attempt to open any of the three modules while power is applied to the system. They are not hot pluggable. Immediate system shutdown and loss of data will occur. To open the Processor and Memory Module: 1. If the computer is on, place the computer in Standby mode. See Chapter - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 65
3-10 Compaq ProLiant 8500 Servers Setup and Installation Guide 2 1 2 1 2 Figure 3-7. Opening the Processor and Memory Module Removing the Processor and Memory Module 1. Follow steps 1 through 3 of the preceding section, "Opening the Processor and Memory Module." 2. Press the module stop latches - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 66
III Xeon processor manageability feature. It can be used for network inventory and tracking purposes. Compaq ProLiant 8500 servers are of data will occur. To remove media module: 1. If the server is on, place it in Standby mode and disconnect the power cord(s). See Chapter 2, "Server Installation - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 67
3-12 Compaq ProLiant 8500 Servers Setup and Installation Guide 1 2 2 1 2 Figure 3-9. Opening the media module 4. Press : The top panel labels provide instructions on installing processors, DIMMs, processor power modules, and hard drives. 6. To reassemble the server, slide the module in until - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 68
Server Operation 3-13 Refer to the following figure to identify components in the Media Module. 1 2 3 4 5 8 7 6 Figure 3-10. Media Module components 1 CD-ROM drive signal/power cable 5 Power switch/LED and thermistor cable 2 Diskette drive signal cable 6 Media backplane assembly 3 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 69
provided as an overview for installing hardware option upgrades. Compaq recommends that you use the documentation provided with the hardware option for complete installation instructions. You can also refer to the Compaq ProLiant 8500 Hardware Installation and Configuration poster included in the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 70
Compaq ProLiant 8500 Servers Setup and Installation Guide Installing a Hot-Plug Power Supply The ProLiant 8500 ships with either one or two hot-plug power supplies depending on the model. The system power in the ProLiant 8500 Server does not have to be shut off to replace one of the power supplies - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 71
required to cool the internal components of the server. 3 1 2 Figure 4-2. Removing a power supply 4. Remove the protective covers from the connector on the new power supply. See the installation documentation that came with the power supply for more information. Keep the protective covers for - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 72
4-4 Compaq ProLiant 8500 Servers Setup and Installation Guide 2 1 Figure 4-3. Securing the hot-plug power supply 8. Plug in the power cord. If desired, use the plastic retainer to secure the AC cord to the plastic loop provided on the power supply. Leave an 8-inch service loop for the plug. This - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 73
Hardware Options 4-5 Installing a Pentium III Xeon Processor and Processor Power Module The ProLiant 8500 ships with one to eight Pentium III Xeon processors installed, and it is capable of supporting up to eight processors and eight processor power modules. Each processor requires an associated - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 74
4-6 Compaq ProLiant 8500 Servers Setup and Installation Guide 1 2 3 4 11 12 5 6 7 8 13 14 Figure 4-6. Processor board layout 9 10 Table 4-1 Processor/Processor Power Module Socket and Associated Bus/Core Ratio Switch Locations Item Component Item Component 1 Processor Socket 1 and associated - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 75
Hardware Options 4-7 To install a processor power module and a Pentium III Xeon processor in the Processor and Memory Module, refer to one of the the server is on, place it in Standby. See Chapter 2, "Server Installation." 2. Remove the Processor and Memory module. See Chapter 3, "Server Operation." - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 76
4-8 Compaq ProLiant 8500 Servers Setup and Installation Guide 4. Rotate the ejector levers 1 fully to unseat the processor terminator board from the socket. Remove the processor terminator board by pulling it out by the handle 2. Retain for future use. NOTE: If you remove a Pentium III Xeon - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 77
hear the ejectors click into a locked position. CAUTION: The processor power module must be installed before the accompanying Pentium III Xeon processor. Attempting to install the processor power module after the Pentium III Xeon processor has been installed could damage the electronic components on - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 78
4-10 Compaq ProLiant 8500 Servers Setup and Installation Guide 9. Align the new Pentium III Xeon processor with the processor socket. Install the processor 1, and rotate the ejector levers inward 2 to fully seat and lock the processor. 2 2 1 Figure 4-10. Installing the Pentium III Xeon processor - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 79
on determining which configuration is best for your system. ProLiant 8500 servers have two processor buses. In the following figure, processor the server is on, place it in Standby and disconnect the power cord(s). See Chapter 2, "Server Installation." 2. Remove the Processor and Memory module. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 80
4-12 Compaq ProLiant 8500 Servers Setup and Installation Guide WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. 3. Loosen the thumbscrew of - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 81
processor power module server. See Chapter 2, "Server Installation." SDRAM Memory You can expand computer memory by installing industry-standard Dual Inline Memory Modules (DIMMs) into the memory expansion boards. The following requirements must be met when installing additional memory: s Supports - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 82
4-14 Compaq ProLiant 8500 Servers Setup and Installation Guide CAUTION: Use only Compaq DIMMs. DIMMs from other sources may affect data integrity adversely. To install more memory, refer to one of the following installation sources: s For a detailed text and illustrated procedure, refer to the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 83
. Removing the memory board NOTE: The memory board is part of the system interconnect scheme and must be seated properly for server start up. expansion board can cause the memory expansion board to flex and could result in damage. Always support the memory expansion board or apply counter pressure - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 84
4-16 Compaq ProLiant 8500 Servers Setup and Installation Guide 7. Insert each DIMM 2 directly into the socket until the module is properly seated. 3 2 1 Figure 4-15. Installing DIMM memory module in memory board 8. Secure the DIMM by closing the socket latches 3. 9. Verify that the two DIMMs - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 85
memory expansion board and Processor and Memory module by reversing steps 1 through 3. 11. Turn on the server. See Chapter 2, "Server Installation." 12. If the server does not power ProLiant 8500 supports up to four 1-inch, Ultra2, Single Connector Assembly (SCA), hot-plug hard drives. The server - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 86
4-18 Compaq ProLiant 8500 Servers Setup and Installation Guide The following illustration shows the media module populated with four 1-inch hard drives 1-4, IMD 5, a diskette drive 6, and a CD-ROM drive 7 installed. 4 3 2 5 1 6 7 Figure 4-17. Four 1-inch - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 87
in the lowest numbered bay. If several drives are installed, the system boot drive should be installed in the lowest numbered bay. s In order to installed in unused drive bays. The server has one embedded Integrated Smart Array Controller (Ultra2 support). The integrated controller is hardwired - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 88
4-20 Compaq ProLiant 8500 Servers Setup and Installation Guide Installing a Hot Plug SCSI Hard Disk Drive CAUTION: Before adding or removing any hot-plug SCSI drives, consult your operating system instructions. Failure to do so could result in loss of data or damage to equipment. To install a hot- - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 89
Installing Hardware Options 4-21 3. Insert the hot-plug drive into the empty drive bay, pushing until securely seated 1. 4. Secure the hot-plug drive in the drive cage by swinging the ejector lever inward 2, as shown below. 1 2 Figure 4-19. Installing a SCSI hard drive CAUTION: Before removing any - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 90
4-22 Compaq ProLiant 8500 Servers Setup and Installation Guide Hot-Plug SCSI Hard Drive Indicators The Hot-Plug SCSI hard drives used with ProLiant 8500 servers have three LEDs that indicator the status of the drives: 1 - Activity, 2 - Power/Online, and 3 - Fault. These indicators are shown in the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 91
green whenever it is being rebuilt. A replaced drive is restored from data stored on the other drives. s Never turn a ProLiant Storage System off while the server controlling it is powered on. Doing so will cause the server's Smart Controller to mark the drives as "failed." This could result - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 92
4-24 Compaq ProLiant 8500 Servers Setup and Installation Guide NOTE: When a drive configured for fault tolerance is If the server is on, place it in Standby mode and disconnect the power cord(s). See Chapter 2, "Server Installation." 2. If the external storage device is on, disconnect the power. 3. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 93
The ProLiant 8500 server supports PCI Hot Plug. PCI Hot Plug and the server's operating system work together to allow the following hot-plug actions: s Hot-replacement of adapters - This feature allows you to replace a failed adapter with an identical adapter without powering down the server. s Hot - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 94
4-26 Compaq ProLiant 8500 Servers Setup and Installation Guide Locating the I/O Expansion Slots The I/O expansion slots are located in the I/O Module, and are accessed by sliding the server out of the rack and opening the top access panel as described in Chapter 3, "Server Operation." WARNING: To - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 95
in the following figure for one slot) provide a visual reference of the status of each slot. The LEDs are viewed from the rear of the server or by opening the top access panel. 1 2 Figure 4-23. PCI Hot Plug LED indicators from rear of - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 96
4-28 Compaq ProLiant 8500 Servers Setup and Installation Guide Each PCI Hot Plug Button 3 is problem with the slot, the PCI board, or the driver. Check the green LED before opening the slot. X Green LED OK to Open Slot Status On No Power is applied to slot. Flashing No Off Yes Power - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 97
, you will not be able to power up the slot. Software Components The software components include the Compaq PCI Hot Plug Utility, the Compaq Remote Monitor service (CPQRCMC), the Compaq Systems Management driver (SYSMGMT.SYS), and hot-plug aware drivers. The Compaq PCI Hot Plug Utility allows you to - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 98
30 Compaq ProLiant 8500 Servers Setup and Installation Guide Installing PCI Support Compaq Support Software for Microsoft Windows NT 4.0 (NT SSD), version 2.0 or later, contains all the software components to support Compaq PCI Hot Plug. Included on the NT SSD are hot-plug aware device drivers, such - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 99
: s Novell Event Bus (NEB) s Novell Configuration Manager (NCM) s OEM Specific System Bus Driver (SBD) s Novell Configuration Manager Console (NCMCON) Device drivers Other boards Installation tools Installing PCI Support Compaq provides PCI Hot Plug support for NetWare via the Novell Software - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 100
Compaq ProLiant 8500 Servers Setup and Installation Guide SCO UnixWare Supported PCI Functionality Compaq support of PCI Hot Plug under UnixWare 7.01 provides hotreplacement, hot-upgrade, and hot-addition for a variety of boards. You can eliminate downtime when you replace faulty adapters, upgrade - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 101
online PCI Hot Plug Administration Guide on the Systems Reference Library CD. Supported I/O Expansion Boards The I/O board of the ProLiant 8500 has eleven PCI Hot Plug expansion slots. These slots are distributed among three PCI buses as shown in Table 4-4. The ProLiant 8500 server is shipped with - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 102
Non-Hot Plug Expansion Boards You can use non-hot plug expansion boards in the ProLiant 8500 server, but you must install them according to the following procedure. 1. Back up your server data. 2. Shut down the operating system in an orderly manner as directed in your operating system instructions. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 103
slide the I/O Module into the server. 7. Power up the server. 8. Run the System Configuration Utility as described in Chapter 6, "Server Configuration." Hot Plug Expansion Boards The PCI slots of the ProLiant 8500 I/O board are Hot Plug capable and support a variety of industry-standard expansion - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 104
4-36 Compaq ProLiant 8500 Servers Setup and Installation Guide 3. Press on the top 1 of the appropriate expansion slot release lever and open the lever toward the rear 2 of the expansion slot. 4. Remove the expansion - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 105
be sure the L-shaped slot keeper tabs on the plastic expansion board guide are positioned over the forward end of the expansion board. Using the is especially important when expansion boards are added or the server is moved. 10. Activate power to the slot through the PCI Hot Plug software application - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 106
Compaq ProLiant 8500 Servers Setup and Installation Guide Removing or Replacing a PCI Hot Plug Expansion Board 1. Open the top access door. 2. Use the PCI Hot Plug Button or software application to turn power off to the slot. The green LED will flash during the power power down and subsequent data - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 107
4-39 Replacing Hot Plug Fans The ProLiant 8500 server ships with two hot-plug fans. Fan 1 is closest to the rear of the server. Each fan has LEDs that indicate the status of the fan as follows: s No light - power is not applied to the fan s Green light 1 - power is applied to the fan and fan - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 108
4-40 Compaq ProLiant 8500 Servers Setup and Installation Guide 1. Open the top access door. 2. Press the locking latches in 1 and lift the failed hot-plug fan (either 1 or 2) out of the I/O Module 2. 2 1 Figure 4-30. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 109
describes the features and set up of the ProLiant 8500 server Integrated Smart Array Controller (Ultra2 support) . Features The ProLiant 8500 Dual Channel Integrated Smart Array Controller is a dual Ultra2 SCSI array controller. Both channels support Low Voltage Differential (LVD) SCSI devices. The - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 110
5-2 Compaq ProLiant 8500 Servers Setup and Installation Guide The location of the external connector for Port 1 is shown in the Integrated Array Bypass" for installation instructions. For external RAID support, use an array controller such as the Compaq 3200 Array Controller. The Option ROM-based - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 111
Bypass This document describes the installation of the Compaq ProLiant 8500 Integrated Array Bypass kit. Use this kit if you want to bypass the Integrated Smart Array Controller (Ultra2 support) and use an optional controller such as the Compaq 3200 Array Controller. WARNING: To reduce the risk - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 112
5-4 Compaq ProLiant 8500 Servers Setup and Installation Guide 5. Remove the Array Enabler Board as shown in the following figure. 2 1 Figure 5-2. Removing the Array Enabler Board 6. Install the Integrated Array assembly as shown in - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 113
and routing of the cable in the preceding figure depends on which slot the optional array controller board occupies. 9. Close the top access panel and power up the server. 10. Configure the new controller with the ACU as described later in this chapter. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 114
Compaq ProLiant 8500 Servers Setup and Installation Guide Option ROM-Based Array Configuration Utility The Option ROM-based Array Configuration Utility allows you to setup a simple configuration during Power all of the SCSI buses supported At the initial screen, data on the drive. If - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 115
This utility: s Provides a graphical view of Compaq drive array configurations s Provides express or custom initial configuration s Supports adding additional capacity s Supports RAID 0, 1/0+1, and 5 fault-tolerant configurations s Supports Raid level and stripe size migration s Helps optimize your - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 116
5-8 Compaq ProLiant 8500 Servers Setup and Installation Guide Starting the Compaq Array Configuration Utility The Compaq ProLiant 8500 server is shipped with the Array Configuration Utility (ACU) on the SmartStart and Support Software CD. You would normally start the utility as described in the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 117
drive is full of data, you can extend the logical drive when there is free space on the array. If there is no free space on the array, you can add drives to the array and proceed to extend the logical drive. IMPORTANT: Logical drive extension is not supported by all operating - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 118
5-10 Compaq ProLiant 8500 Servers Setup and Installation Guide RAID Level and Stripe Size Migration Use the Online RAID Level or Stripe Size Migration screen to: s Reconfigure a currently configured logical drive to a new fault-tolerance (RAID) level s Change an existing logical drive's stripe size - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 119
file to access instructions on loading and using CPQONLIN.NLM. SmartStart and Support Software CD You can run the Array Configuration Utility directly from the SmartStart and Support Software CD. 1. Insert the SmartStart and Support Software CD in the CD drive and power up the server. A menu is - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 120
indicating that you are running with a default configuration will occur each time you boot the system. See "Powering Up Your Server" in Chapter 2 for more details. To install the SmartStart and Support Software CD: 1. With your server turned on, locate the CD-ROM drive. 2. Push the button to release - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 121
6-2 Compaq ProLiant 8500 Servers Setup and Installation Guide 3. Place the SmartStart and Support Software CD in the tray (label facing up), handling the CD from the edges, not by the flat surfaces of the disc. Figure 6-1. Installing a CD - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 122
Management Log provides greater serviceability to your Compaq server by being capable of recording hundreds of events when service is required. It also Log requires Compaq Operating Systemdependent drivers for full support. Refer to the Compaq Support Software CD for instructions on installing - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 123
Compaq ProLiant 8500 Servers Setup and Installation Guide Multiple Ways of Viewing the Log You can view an event in the Integrated Management Log in four ways: s From the Integrated Management Display (IMD) s From within Compaq Insight Manager s From within Compaq Compaq SmartStart and Support - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 124
Integrated Management Log 7-3 To run the System Configuration Utility: 1. Boot the computer from the Compaq SmartStart and Support Software CD. 2. From the Compaq System Utilities screen, select Run System Configuration Utility. 3. Select Continue. 4. Select Review or Modify Hardware Settings and - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 125
7-4 Compaq ProLiant 8500 Servers Setup and Installation Guide 11. At the server prompt Save the Configuration and Restart drive, you will be asked if you would like to upgrade your system partition. You should upgrade your System Configuration Utility at this time. Customizing Management Display - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 126
Name Enter up to 2 lines of no more than 14 characters each. An example might be to name the server by department, for example: CUST SERVICE WESTERN REGION Asset Tag Enter the server asset tag. Enter up to 2 lines of 16 characters each. Primary Operating System Enter the primary operating system of - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 127
7-6 Compaq ProLiant 8500 Servers Setup and Installation Guide Administrator Information Name This field contains the name Enter up to 2 lines of no more than 14 characters each. Service Information Name This field contains the name of the service provider. Enter up to 2 lines of no more than 14 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 128
each. For example, you might enter server history information such as: SERVICE CONTRACT 1C2002 Standard Integrated Management Display Fields current server ROM. Bootblock Date This is the month/date/year of the current server Bootblock. Memory This field shows the total memory of the server. - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 129
7-8 Compaq ProLiant 8500 Servers Setup and Installation Guide F1 Prompt Selecting this menu choice enables you to continue booting without a keyboard or monitor. This feature is useful for service and diagnostic purposes, allowing you to continue the boot up process without attaching a monitor and - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 130
Integrated Management Log 7-9 Display Symbols There are three different display symbols used to indicate your options as you scroll through the menus. These symbols are the Up, Down, and Selector arrows. Type of Symbol Right Arrow Up Arrow Down Arrow Table 7-1 Integrated Management Display - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 131
7-10 Compaq ProLiant 8500 Servers Setup and Installation Guide Navigation To navigate through the menus, use the four buttons shown in the Figure 7-2. key and allows you to travel back up the menu. LCD-011.EPS COMPAQ PROLIANT XXXX ESC 1 2 4 3 Figure 7-2. Integrated Management Display buttons - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 132
. Menu Structure The following outline shows the structure of each menu and submenu in the order in which it appears: Events s Event List Administration Information s Server Server Name Asset Tag - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 133
7-12 Compaq ProLiant 8500 Servers Setup and Installation Guide Operating System Other s Administrator Name Phone Pager Other s Service Name Phone Pager Other s Custom Menu Item (if entered) s Custom Menu Screen (if entered) System Information s ROM Date s Bootblock Date s Memory - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 134
the Event List 1. From Compaq Insight Manager, select the appropriate server then select View Device Data. 2. The selected server is displayed with buttons list, follow the instructions below. 1. From the Insight Manager, select the appropriate server. The selected server is displayed with buttons - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 135
7-14 Compaq ProLiant 8500 Servers Setup and Installation Guide Compaq Survey Utility The Compaq Survey Utility is a serviceability tool available for Windows NT and Novell NetWare that delivers online configuration capture and comparison to maximize server availability. It is available on the Compaq - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 136
but may have a short. Refer to the "System Short" section in the Compaq Servers Troubleshooting Guide. 2. Check the power supplies. The following settings indicate that the power switch is on and the power supply is in a "power on" delay mode: Top LED begins flashing (green) Bottom LED ON (solid - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 137
Compaq ProLiant 8500 Servers Setup and Installation Guide Compaq initialization screen. 3. Check for the IMD memory test message. The monitor shows the memory count and the memory initialization. 4. Observe the memory count displayed. 5. Check for the IMD BIOS not on, power down the server. Check the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 138
provided with ProLiant 8500 Server provide a closed-loop checking mechanism for verifying proper component mating between critical server components. These indicators are located in the I/O Module in front of the system fans. They are operated using standby power provided by the power supplies. If - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 139
8-4 Compaq ProLiant 8500 Servers Setup and Installation Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Figure 8-1. Accessing System Interconnect Status Indicator LEDs Table 8-1 System Interconnect Status Indicators Indicator 1 Component Emergency Shutdown1 Indicator - - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 140
power supplies plugged in. Running System Diagnostics 1. Make sure there is good facility power applied to the server. 2. With the power to the server still turned off, check the LEDs on the power supplies Tools" chapter of the Compaq Servers Troubleshooting Guide for details on other diagnostic - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 141
For the purpose of regulatory compliance certifications and identification, your Compaq ProLiant 8500 server is assigned a Compaq Series Number. The Compaq Series number for this product is: Series ES2000. The Compaq ProLiant 8500 server Series Number can be found on the Regulatory Compliance label - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 142
A-2 Compaq ProLiant 8500 Servers Setup and Installation Guide Class B devices are those that may reasonably be expected to radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 143
. To identify this product, refer to the Part, Series, or Model number found on the product. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user's authority to - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 144
A-4 Compaq ProLiant 8500 Servers Setup and Installation Guide European Union Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 145
maintenance. Laser Safety Warnings WARNING: To reduce the risk of exposure to hazardous radiation: s Do not try to open the laser device enclosure. There are no user- serviceable only Compaq Authorized Service technicians to repair the laser device. Compliance with CDRH Regulations The Center for - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 146
A-6 Compaq ProLiant 8500 Servers Setup and Installation Guide Laser Product Label The following label or equivalent is located on the surface of the Compaq supplied laser device. This label indicates that the product is classified as a CLASS 1 LASER PRODUCT. This label appears on a laser device - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 147
. Replacement is to be done by a Compaq Authorized Service Provider using the Compaq spare designated for this product. For more information about battery replacement or proper disposal, contact your Compaq Authorized Reseller or your Authorized Service Provider. WARNING: Your computer contains an - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 148
B Appendix Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 149
B-2 Compaq ProLiant 8500 Servers Setup and Installation Guide Grounding Methods There are several boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. s Use conductive field service tools. s Use a portable field service - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 150
cord sets for use in other countries must meet the requirements of the country where you use the server. For more information on power cord set requirements, contact your Authorized Compaq Dealer. General Requirements The requirements listed below are applicable to all countries: s The length of the - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 151
C-2 Compaq ProLiant 8500 Servers Setup and Installation Guide Country-Specific Requirements Use the following table to identify the appropriate accredited agency in your country. Table C-1 Power Cord Set Requirements - By Country Country Argentina Australia Austria Belgium Canada Chile China - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 152
the 3 pin Italian style plug conforming to th4e CEI.23-16-VII standard. 5. Flexible cord must be Type RVV, 3-conductor, 1.0 mm2 conductor size. Power cord set fittings (appliance coupler and wall plug) must bear the CCEE certification mark. 6. The wall plug must bear a KIATECH mark. Flexible cord - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 153
D Appendix Server Specifications Table D-1 Compaq ProLiant 8500 Server Specifications Dimensions Height 12.0 in Depth 27.0 in Width 17.5 in Weight (no drives and two power supplies) 111 lb Input Requirements (per power supply) Low Range Rated Input Voltage 100 to 120 V Rated Input - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 154
features 5-7 NetWare support 5-11 running from SmartStart 5-11 running online 5-10 starting 5-8 Windows NT support 5-10 Array service provider 1-9 Auto Line Sensing 1-7 Automatic Server Recovery See ASR-2 B battery recycling or disposal A-7 battery replacement warnings A-7 blanking panels 4-19 boot - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 155
2 Compaq ProLiant 8500 Servers Setup and Installation Guide Canadian Notice (Avis Canadien) A-3 capacity expansion, defined 5-8 capacity extension defined 5-9 supported by 5-9 cautions grounding xii Hot Plug I/O Fans 4-39 internal rack temperature 2-5 overheating xii third-party options 2-5 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 156
supported 1-4 upgrades 1-4 disconnecting power 2-27, 3-2 disk controller features 1-5 diskette boot password override 1-14 drive control 1-13 drive, accessing 3-12 drive, illustrated 1-2 write control 1-13 display, Integrated Management 1-10 drive arrays, capacity extension 5-9 drive bay 1-5 drivers - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 157
4 Compaq ProLiant 8500 Servers Setup and Installation Guide grounding methods B-2 receptacles 2-4 strap specifications B-2 straps B-2 suggested equipment for B-2 H half-height drive bay 1-5 hard drives cages, accessing 3-6 cages, number of 1-5 indicators (LEDs) 4-22 Hardware Installation and - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 158
manaegment 1-10 service information 7-6 standard fields 7-7 system information 7-12 unviewed events 7-11 verifying memory 4-17 viewing 7-2 IML events 7-2 overview 1-12, 7-1 server management 1-10, 1-12 viewing 7-2 Index 5 indicators Interconnect Status 3-4 power supplies 4-4 System Interconnect - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 159
6 Compaq ProLiant 8500 Servers Setup and Installation Guide interfaces CPQRCMC 4-29 parallel control 1-13 ROMPaq 1-9 standard 1-6 internal hot plug drive bays features 1-5 interrupts 1-10 IRC overview 1-12 server management 1-10, 1-12 IRQs 1-10 K keyboard connecting 2-2 connector 2-26 interface 1-6 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 160
Event Bus (NEB) 4-31 Open Data-Link Interface 4-31 Software Support Diskette 4-31 NT See Windows NT NT SSD 4-30 NWPA 4-31 O ODI See Open Data-Link Interface OEM Specific System Bus Driver (SBD) 4-31 OFF 2-29 ON 2-29 online help 5-8 online migration changing RAID level 5-10 changing stripe size 5-10 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 161
8 Compaq ProLiant 8500 Servers Setup and Installation Guide overview system interconnect 3-4 Windows NT 4-29 P panel opening 3-7 top access 3-6 parallel interface control 1-13 port connector 2-26 partition, system 1-11 parts proper handling B-1 storing B-1 transporting B-1 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 162
Procedure Calls (RPC) S SBD See OEM Specific System Bus Driver SCO Admin 4-32 SCO UNIX, Hot Plug 4-32 SCSI connector 2-26 devices 4-19 ID settings 2-2 SDRAM See memory security features 1-13 serial number, Processor 3-11 series number A-1 server accessing components 3-6 configuration 1-10 features - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 163
Compaq ProLiant 8500 Servers Setup and Installation Guide server registration 1-14 Server Setup and Management pack 2-2, 6-2 Servers Troubleshooting Guide 7-14 Service Information 7-6 service 1-7 memory, features 1-4 partition 6-1 partition, creation of 1-11 partition, upgrading 7-4 power 4-2 - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 164
2-4. See temperature, maximum recommended ambient tools conductive field service type B-2 required for installation 2-7 top access panel general 3-6 opening 3-7 troubleshooting hard drive LEDs 8-2 IMD 8-2 PCI Hot Plug LEDs 8-2 power supplies 8-1 startup sequence 8-1 system diagnostics 8-5 System - Compaq ProLiant 8500 | Compaq ProLiant 8500 Setup and Installation Guide - Page 165
12 Compaq ProLiant 8500 Servers Setup and Installation Guide power cord grounding plug 3-2 power cords 3-2 power supplies 2-27 voiding warranty xi warranty 1-9 web-based management 1-12 website PCI Hot Plug information 4-33 registration 1-14 server and option information 1-9 Windows NT support
ProLiant 8500 Servers
Setup and Installation Guide
First Edition (May 1999)
Part Number 323333-001
Compaq Computer Corporation