Page 108 highlights
4-40 Compaq ProLiant 8500 Servers Setup and Installation Guide 1. Open the top access door. 2. Press the locking latches in 1 and lift the failed hot-plug fan (either 1 or 2) out of the I/O Module 2. 2 1 Figure 4-30. Removing hot-plug I/O Fan 2 3. Lower the new hot-plug fan into the I/O Module until it rests on the I/O board connector , holding the locking latches . Push the fan into the connector and release the locking latches to engage the fan. 1 2 Figure 4-31. Installing a new hot-plug fan 1 4. Verify that the fan is producing airflow and that the LED is green. 5. Close the top access door.
4-40
Compaq ProLiant 8500 Servers Setup and Installation Guide
1.
Open the top access door.
2.
Press the locking latches in
1
and lift the failed hot-plug fan (either 1
or 2) out of the I/O Module
2
.
1
2
Figure 4-30.
Removing hot-plug I/O Fan 2
3.
Lower the new hot-plug fan into the I/O Module until it rests on the I/O
board connector
±
, holding the locking latches
²
. Push the fan into the
connector and release the locking latches to engage the fan.
1
2
Figure 4-31.
Installing a new hot-plug fan 1
4.
Verify that the fan is producing airflow and that the LED is green.
5.
Close the top access door.