1-2 1-2-2-3 1-3-1-1 1-3-1-3 1-3-4-1 1-3-4-3 1-4-1-1 2-1-2-3 2-2-3-1 Memory module not being properly identified or used Faulty memory module or faulty main board ROM BIOS checksum failure Faulty main board DRAM refresh failure Faulty main board Keyboard controller test failure Faulty keyboard or faulty main board RAM failure on address line Faulty memory module or nnnn faulty main board RAM failure on data bits Faulty memory module or nnnn of high byte on memory faulty main board bus RAM failure on data bits Faulty memory module or nnnn of low byte on memory faulty main board bus Check ROM copyright notice Faulty main board failure Interrupt mask register failure Faulty main board Table 3-2 lists (in alphabetical order) system error messages that may appear on the display during the boot routine or during normal computer operation. The CMOS battery does not have enough charge to power the computer. Connector loose or diskette faulty. Extended memory not configured properly or failed at memory address nnnn. CMOS battery completely discharged. Faulty CMOS battery or main board. Faulty or incorrectly inserted diskette in drive. Faulty diskette drive. Faulty main board. Faulty or loose external cable. Faulty or improperly seated memory module. Faulty main board. 3-2