Part Six GTS 800 Interface To begin tracking intruder aircraft: 1. Press the cursor knob and highlight STBY. 2. Turn the small right knob to select OPER. 3. Press ENT to confirm operating mode and begin tracking intruder aircraft. Operating Mode is confirmed by the display of "OPER" in the upper right-hand corner of the Traffic Page. NOTE: The FAILED message occurs when the system detects an error and prohibits further traffic display operation as long as this message stays on the screen. User-initiated Test NOTE: A user-initiated test can only be performed when in standby or failed mode. In addition to the power-up test, the GTS 800 series unit performs a continuous self-test. This continuous self-test is performed several times per minute. A userinitiated test of the GTS 8XX series unit interface can also be performed. To perform a user-initiated test: 1. Turn the small right knob to select the Traffic Page. 2. From the Traffic Page, press MENU to display the Page Menu. 3. Turn the small right knob to select "Self Test?" and press ENT. Voice Announcements See the GTS 8XX Series Pilot's Guide for information on voice announcements. Switching Between Standby and Operating Modes The unit must be in operating mode for traffic to be displayed. The ability to switch out of standby into operating mode on the ground is especially useful for scanning the airspace around the airport before takeoff. To switch into Operating Mode from Standby Mode: 1. Press the cursor knob and highlight "STBY". Turn the small right knob to select "OPER?". 2. Press ENT to confirm and place the GTS 8XX series unit in operating mode. NOTE: The GTS 8XX series unit switches out of standby into the 6-NM display range. If your aircraft has a squat switch and you do not manually switch out of standby, the GTS 8XX series unit will automatically switch out of standby 8 to 10 seconds after takeoff. To switch into Standby Mode from the Traffic Page: 1. Press the cursor knob and highlight "OPER". 2. Turn the small right knob to select "STBY?". 3. Press ENT to confirm and place the GTS 8XX series unit in standby mode. NOTE: If your aircraft has a squat switch, STBY is not displayed while you are airborne but will go into standby 24 seconds after landing. This delay allows the GTS 8XX series unit to remain in the operating mode during a touch-and-go maneuver. 66 190-00356-30 Rev H

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

66
Part Six
GTS 800 Interface
To begin tracking intruder aircraft:
1.
Press the
cursor
knob and highlight
STBY
.
2.
Turn the
small right
knob to select
OPER
.
3.
Press
ENT
to confirm operating mode and begin
tracking intruder aircraft.
Operating Mode is confirmed by the display
of “OPER” in the upper right-hand corner of
the Traffic Page.
NOTE:
The FAILED message occurs when the system
detects an error and prohibits further traffic display oper-
ation as long as this message stays on the screen.
User-initiated Test
NOTE:
A user-initiated test can only be performed when
in standby or failed mode.
In addition to the power-up test, the GTS 800 series
unit performs a continuous self-test. This continuous
self-test is performed several times per minute. A user-
initiated test of the GTS 8XX series unit interface can
also be performed.
To perform a user-initiated test:
1.
Turn the
small right
knob to select the Traffic
Page.
2.
From the Traffic Page, press
MENU
to display
the Page Menu.
3.
Turn the
small right
knob to select “Self Test?”
and press
ENT
.
Voice Announcements
See the GTS 8XX Series Pilot’s Guide for informa
-
tion on voice announcements.
Switching Between Standby and Operating Modes
The unit must be in operating mode for traffic to
be displayed. The ability to switch out of standby into
operating mode on the ground is especially useful for
scanning the airspace around the airport before takeoff.
To switch into Operating Mode from Standby
Mode:
1.
Press the
cursor
knob and highlight
STBY
”. Turn the
small right
knob to select
“OPER?”
.
2.
Press
ENT
to confirm and place the GTS 8XX
series unit in operating mode.
NOTE:
The GTS 8XX series unit switches out of standby
into the 6-NM display range. If your aircraft has a squat
switch and you do not manually switch out of standby,
the GTS 8XX series unit will automatically switch out of
standby 8 to 10 seconds after takeoff.
To switch into Standby Mode from the Traffic Page:
1.
Press the
cursor
knob and highlight
“OPER”
.
2.
Turn the
small right
knob to select
STBY
?”.
3.
Press
ENT
to confirm and place the GTS 8XX
series unit in standby mode.
NOTE:
If your aircraft has a squat switch,
STBY
is not
displayed while you are airborne but will go into standby
24 seconds after landing. This delay allows the GTS 8XX
series unit to remain in the operating mode during a
touch-and-go maneuver.
190-00356-30 Rev H