HP ProLiant DL288 HP ProLiant DL288 G6 Server Maintenance and Service Guide
HP ProLiant DL288 Manual
View all HP ProLiant DL288 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant DL288 manual content summary:
- HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 1
HP ProLiant DL288 G6 Server Maintenance and Service Guide Part number 663204-001 First edition July 2011 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 3
Contents Customer self repair ...1 Parts only warranty service...1 Illustrated parts catalog ...12 Mechanical components / 4 3.5" HDD model 12 Mechanical instructions ...40 Server warnings and cautions...40 HP Trusted Platform Module...41 Symbols on equipment...41 Powering down the server - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 4
menu bar ...142 BIOS update ...148 Clear CMOS...148 Power-On Self-Test (POST)...148 POST error indicators ...149 POST error descriptions ...149 POST related troubleshooting...150 SETSYS utility...151 Physical and operating specifications 152 System unit...152 Index ...157 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 6
pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie "pi - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 7
due categorie di parti CSR: • Obbligatorie-Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio. • Opzionali-Parti la cui riparazione da parte del cliente è facoltativa. Si - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 8
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 9
componentes CSR se clasifican en dos categorías: • Obligatorio-componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 10
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSRonderdeel, verzendt - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 11
Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto. OBSERVAÇÃO: Algumas peças - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 12
Customer self repair 8 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 13
Customer self repair 9 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 14
Customer self repair 10 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 15
Customer self repair 11 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 16
Illustrated parts catalog Mechanical components / 4 3.5" HDD model Table 1 Mechanical Components Spare Parts List / 4 3.5" HDD Model Item Description 1 Air baffle 2 Rail kit 3 Hard drive cage for 4 3.5" HDDs (includes control panel) 4 Hardware/Plastics Kit ASSY, BLANK,SFF BRKT, PCI,LOW - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 17
Mechanical components / 8 3.5" HDD model Table 2 Mechanical Components Spare Parts List / 8 3.5" HDD Model Item Description 1 Air baffle 2 Rail kit 3 Hard drive cage for 8 3.5" HDDs(includes control panel) 4 Hardware/Plastics Kit ASSY, BLANK,SFF BRKT, PCI,LOW PROFILE, ARRAY CONT BRKT, - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 18
Mechanical components / 8 2.5" HDD model Table 3 Mechanical Components Spare Parts List / 8 2.5" HDD Model Item Description 1 Air baffle 2 Rail kit 3 Hard drive cage for 8 2.5" HDDs (includes control panel) 4 Hardware/Plastics Kit ASSY, BLANK,SFF BRKT, PCI,LOW PROFILE, ARRAY CONT BRKT, - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 19
Mechanical components / 12 3.5" HDD model Table 4 Mechanical Components Spare Parts List / 12 3.5" HDD Model Item Description 1 Air baffle 2 Rail kit 3 Hard drive cage for 12 3.5" HDDs (includes control panel) 4 Hardware/Plastics Kit ASSY, BLANK,SFF BRKT, PCI,LOW PROFILE, ARRAY CONT - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 20
Mandatory1 507262-001 Mandatory1 1Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which customer self repair is optional. These parts are also designed for - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 21
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 22
met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ém são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 23
Illustrated parts catalog 19 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 24
The system supports five kinds of HDD configurations, three types of PCI cage and three types of power supply unit. The following table lists the detailed system configurations. - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 25
/ 4 3.5" HDD Model Item Description 1 System board, Intel 5500 series processors System board, Intel 5500 & 5600 series processors 2 Power supplies (all support hot-plug) Power supply 460 W Power supply 750 W Power supply 460 W 94% Power supply 750 W 94% 3 DC Converter Power Backplane - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 26
Table 7 System Components Spare Parts List / 4 3.5" HDD Model Item Description 8 Optical disc drive (optional) SPS-DRV,ODD, SLIM SATA DVD-ROM SPS-DRV,ODD, SLIM SATA DVD RW 9 Hard drives 3.5" hot-plug SAS hard drives with carriers 72 GB 15,000 rpm 146 GB 15,000 rpm 300 GB 15,000 rpm 400 GB - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 27
Table 7 System Components Spare Parts List / 4 3.5" HDD Model Item Description 10 Backplane four bays SAS/SATA hard drive 11 FH/FL PCI-E riser card PCI-E x16+2PCI-X 3PCI-EX8 2PCI-EX8 PCI-E x16 12 LP PCI-E riser card PCI-E x16 13 TPM Module (Must be replaced with system board if present) 14 Dedicated - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 28
/ 8 3.5" HDD Model Item Description 1 System board, Intel 5500 series processors System board, Intel 5500 & 5600 series processors 2 Power supplies (all support hot-plug) Power supply 460 W Power supply 750 W Power supply 460 W 94% Power supply 750 W 94% 3 DC Converter Power Backplane - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 29
Table 8 System Components Spare Parts List / 8 3.5" HDD Model Item Description DIMM, 16GB 4RX4 PC3-8500R-7 Unregistered DIMMs (UDIMMs) DIMM, 1GB 1Rx8 PC3-10600E-9 DIMM, 2GB 2Rx8 PC3-10600E-9 6 Processors, FCLGA 1366 Intel Xeon series PROC,Xeon EP 2.93 Ghz, 8M, 95W PROC,Xeon EP 2.67 Ghz, 8M, - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 30
Table 8 System Components Spare Parts List / 8 3.5" HDD Model Item Description 3.5" hot-plug LFF SAS hard drives with carriers 72 GB 15,000 rpm 146 GB 15,000 rpm 300 GB 15,000 rpm 400 GB 10,000 rpm 450 GB 15,000 rpm 750 GB 7,200 rpm 1 TB 7,200 rpm 3.5" hot-plug SATA hard drives with carriers 160 GB - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 31
/ 8 2.5" HDD Model Item Description 1 System board, Intel 5500 series processors System board, Intel 5500 & 5600 series processors 2 Power supplies (all support hot-plug) Power supply 460 W Power supply 750 W Power supply 460 W 94% Power supply 750 W 94% 3 DC Converter Power Backplane - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 32
Table 9 System Components Spare Parts List / 8 2.5" HDD Model Item Description DIMM, 4GB 2Rx4 PC3-10600R-9 DIMM, 4GB 4Rx8 PC3-8500R-7 LP DIMM, 8GB 2Rx4 PC3-8500R-7 DIMM, 16GB 2RX4 PC3 L-10600R-9 DIMM, 16GB 4RX4 PC3-8500R-7 Unregistered DIMMs (UDIMMs) DIMM, 1GB 1Rx8 PC3-10600E-9 DIMM, 2GB - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 33
Table 9 System Components Spare Parts List / 8 2.5" HDD Model Item Description 8 Optical disc drive (optional) SPS-DRV,ODD, SLIM SATA DVD-ROM SPS-DRV,ODD, SLIM SATA DVD RW 9 Hard drives 2.5" hot-plug SAS hard drives with carriers 36 GB 15,000 rpm DP 72 GB 10,000 rpm SP 72 GB 10,000 rpm DP - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 34
12 3.5" HDD Model Item Description 1 System board, Intel 5500 series processors System board, Intel 5500 & 5600 series processors 2 Power supplies (all support hot-plug) Power supply 460 W Power supply 750 W Power supply 460 W 94% Power supply 750 W 94% 3 DC Converter Power Backplane Assy - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 35
Table 10 System Components Spare Parts List / 12 3.5" HDD Model Item Description DIMM, 16GB 4RX4 PC3-8500R-7 Unregistered DIMMs (UDIMMs) DIMM, 1GB 1Rx8 PC3-10600E-9 DIMM, 2GB 2Rx8 PC3-10600E-9 6 Processors, FCLGA 1366 Intel Xeon series PROC,Xeon EP 2.93 Ghz, 8M, 95W PROC,Xeon EP 2.67 Ghz, - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 36
Table 10 System Components Spare Parts List / 12 3.5" HDD Model Item Description 300 GB 15,000 rpm 400 GB 10,000 rpm 450 GB 15,000 rpm 750 GB 7,200 rpm 1 TB 7,200 rpm 3.5" hot-plug SATA hard drives with carriers 160 GB 7,200 rpm, 1.5Gbps 160 GB 7,200 rpm, 3.0Gbps 250 GB 7,200 rpm, 1.5Gbps - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 37
25 2.5" HDD Model Item Description 1 System board, Intel 5500 series processors System board, Intel 5500 & 5600 series processors 2 Power supplies (all support hot-plug) Power supply 460 W Power supply 750 W Power supply 460 W 94% Power supply 750 W 94% 3 DC Converter Power Backplane Assy - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 38
Table 11 System Components Spare Parts List / 25 2.5" HDD Model Item Description DIMM, 16GB 2RX4 PC3L-10600R-9 DIMM, 16GB 4RX4 PC3-8500R-7 Unregistered DIMMs (UDIMMs) DIMM, 1GB 1Rx8 PC3-10600E-9 DIMM, 2GB 2Rx8 PC3-10600E-9 6 Processors, FCLGA 1366 Intel Xeon series PROC,Xeon EP 2.93 Ghz, 8M - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 39
Mandatory1 Optional2 Mandatory1 1Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which customer self repair is optional. These parts are also designed for - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 40
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 41
-1518. • In Canada, call 1-800-263-5868. • In other locations, refer to the HP website at http://www.hp.com/. For HP technical support: • In North America: ○ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 42
• Applicable error messages • Add-on boards or hardware model number and serial number • Third-party hardware or software model number • Operating system type and revision level Illustrated parts catalog 38 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 43
figures are used in substep items, the alphabetically labeled instructions correspond to the numbered labels on the related figure assist with the hardware configuration: • HP ProLiant DL288 G6 Server Easy set-up CD • IPMI Use conductive field service tools. Removal and replacement procedures 39 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 44
through the entire installation and removal procedures first and make sure you understand them before you begin. Post-installation instructions Observe the following items after installing or removing a server component: 1. Be sure all components are installed according to the described step-by-step - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 45
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. HP Trusted TPM installed and remove the system. Contact an HP authorized service provider for a replacement system board and TPM manual material handling. Removal and replacement procedures 41 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 46
: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system. Powering down the server The server does not completely power down when the power button on the front panel is pressed. The button toggles between On and Standby. The standby - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 47
System cover You need to remove the top cover before you can remove or replace a server component. The top cover needs to be removed to service the SAS/SATA backplane. Top cover To remove the top cover: 1. Loosen the screw on the top cover with a T-10 wrench. 2. Press the latch on - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 48
Figure 2 Reinstalling the Top Cover Drives The server supports the following configurations: • 4 drive bays for 3.5 in. hard disk drives and 1 drive bay for optical disc drive • 8 drive bays for 3.5 in. hard disk drives and 1 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 49
1. Squeeze on the top of the retaining latch attached to the cable end of the connector. 2. Grasp the cable end of the connector and pull it straight up. CAUTION: Always pull the connector-NEVER pull on the cable. Pulling on the cable could damage the cable and result in a failed power supply. - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 50
The following tables provide the system board designators that various cables plug into. For more detailed information about system board components, see "System board components". Table 13 Cable Connections from the System Board Cable To System board designator 20-Pin front panel connector - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 51
Table 15 Drive Cable Connections / 8 3.5" HDD Model Cable SATA 5 connector (optional) To Optical disk drive on the front panel SATA&SAS connector designator J57 Table 16 Drive Cable Connections / 8 2.5" HDD Model Cable PCI storage controller card PCI storage controller card SATA 5 connector ( - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 52
Table 19 Drive Cable Connections / 25 2.5" HDD Model Cable To PCI storage controller card 25 2.5" HDD Backplane PCI storage controller card 25 2.5" HDD Backplane SATA&SAS connector designator 3rd party Mini-SAS connector 1 3rd party Mini-SAS connector 2 Removal and replacement procedures 48 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 53
Drive bay configuration The server supports a maximum of twenty-five 2.5 in. hard disk drive bays. Figure 4 System Drive Bays / 4 3.5" HDD Model Item 1 2 Description Optical disc drive bay (optional) 3.5 in. hard disk drive bays (4) Removal and replacement procedures 49 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 54
Figure 5 System Drive Bays / 8 3.5" HDD Model Item 1 2 Description Optical disc drive bay (optional) 3.5 in. hard disk drive bays (8) Figure 6 System Drive Bays / 8 2.5" HDD Model Item 1 2 Description Optical disc drive bay (optional) 2.5 in. hard disk drive bays (8) Removal and replacement - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 55
Figure 7 System Drive Bays / 12 3.5" HDD Model Item Description 1 3.5 in. hard disk drive bays (12) Figure 8 System Drive Bays / 25 2.5" HDD Model Item Description 1 2.5 in. hard disk drive bays (25) Removal and replacement procedures 51 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 56
Optical disc drive bay The Optical disc drive bay of servers with 8 3.5-inch HDDs, 8 2.5-inch HDDs and 12 3.5-inch HDDs support the optional installation of a 12.7 mm (0.5 in.) optical disc drive, so the following procedure is for servers with 8 3.5-inch HDDs. To remove the optical disc drive: 1. - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 57
IMPORTANT: If you remove an optical disc drive without plans of installing a new one, you must reinstall the blank to maintain proper system airflow. To remove the bezel blank: 1. Poke the hook of the bezel blank with a T-10/15 wrench through the round hole on the top side of the HDD cage. 2. Pull - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 58
To install the optical disc drive: 1. Slide the optical disc drive into the chassis. 2. Secure the optical disc drive to the chassis with the two screws. 3. Connect the SATA and power cables to their corresponding connectors on the optical disc drive. Figure 12 Installing the Optical disc drive - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 59
can accommodate up to twenty-five 2.5-inch hard drives. You can install either SAS hard drives or SATA hard drives in the server. For servers with 4 3.5-inch HDDs, the hard drives installed in the server are labeled from Device 1 to Device 4, from left to right, when viewed from the front of the - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 60
with 8 3.5-inch HDDs, the hard drives installed in the server are labeled from Device 1 to Device 8, from top to bottom, left to right, when viewed from the front of the server. Figure 14 Hard Drive Configuration / 8 3.5" HDD Model Item Description 1-8 SAS/SATA hard drives 1-8 Removal and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 61
with 8 2.5-inch HDDs, the hard drives installed in the server are labeled from Device 1 to Device 8, from top to bottom, left to right, when viewed from the front of the server. Figure 15 Hard Drive Configuration / 8 2.5" HDD Model Item Description 1-8 SAS/SATA hard drives 1-8 Removal and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 62
with 12 3.5-inch HDDs, the hard drives installed in the server are labeled from Device 1 to Device 12, from top to bottom, left to right, when viewed from the front of the server. Figure 16 Hard Drive Configuration / 12 3.5" HDD Model Item 1-12 Description SAS/SATA hard drives 1-12 Removal - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 63
with 25 2.5-inch HDDs, the hard drives installed in the server are labeled from Device 1 to Device 25, from top to bottom, left to right, when viewed from the front of the server. Figure 17 Hard Drive Configuration / 25 2.5" HDD Model Item 1-25 Description SAS/SATA hard drives 1-25 Removal - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 64
hard disk carrier button to release the ejector lever. 2. Use the HDD carrier latch to pull the drive out of the cage. Make sure to support the drive when pulling it out of the cage. 3. Pull the hard drive assembly out of the drive bay. Figure 18 Removing the Hard Drive - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 65
2. Push the hard drive assembly into the drive bay until it stops. 3. Press the HDD carrier latch inward until it clicks. Figure 20 Installing the Hard Drive SAS/SATA HDD backplane The following figures show the front and back side of the backplane. Figure 21 Backplane Connectors / 4 3.5" HDD Model - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 66
Figure 22 Backplane Connectors / 8 3.5" HDD Model (component side) Item Description 1 Screw holes 2 LED indicators 3 Headers for hard drive Figure 23 Backplane Connectors / 8 2.5" HDD Model (component side) Item Description 1 LED indicators 2 Screw holes 3 Headers for hard drive - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 67
Figure 24 Backplane Connectors / 12 3.5" HDD Model (component side) Item Description 1 Screw holes 2 LED indicators 3 Headers for hard drive Figure 25 Backplane Connectors / 25 2.5" HDD Model (component side) Item Description 1 Screw holes 2 LED indicators 3 Headers for hard drive - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 68
Figure 26 Backplane Connectors / 4 3.5" HDD Model (solder side) Item 1 2 3 4 Description Power connector Mini SAS connector PROG connector I2C connector Figure 27 Backplane Connectors / 8 3.5" HDD Model (solder side) Item Description 1 Power connector 2 PIC 2 PROG connector 3 PIC 1 PROG - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 69
Item 4 5 6 Description I2C connector Mini SAS connector 1 Mini SAS connector 2 Figure 28 Backplane Connectors / 8 2.5" HDD Model (solder side) Item 1 2 3 4 5 Description PIC 2 PROG connector Power connector I2C connector PIC 1 PROG connector Mini SAS connectors Removal and replacement - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 70
Figure 29 Backplane Connectors / 12 3.5" HDD Model (solder side) Item 1 2 3 4 5 6 7 8 9 Description Power connector 1 PROG connector SAS/SATA expander chip with heat sink covered Mini SAS connector HDD LED connector I2C connector HDD 14 connector HDD 13 connector Power connector 2 Removal and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 71
1 Mini SAS connector 2 WARNING: Ensure that the system is powered off and all power sources have been disconnected from the server. Voltages are present at various locations within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 72
To remove the backplane: 1. Remove all drives out of the drive bays. Refer to the "Optical disc drive bay" and "Hard drives" sections in this chapter for detailed procedures. 2. Remove the top cover. 3. Remove all cables connected to the backplane. 4. Remove the backplane. a. Remove the three screws - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 73
Figure 32 Reinstalling the Backplane 3. Install all necessary cables. Removal and replacement procedures 69 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 74
System board configuration Processor HP ProLiant DL288 G6 Server supports Intel Xeon 5500 and 5600 Series processors. If a single processor is installed, then use socket 1. When two processors are used, the server supports boot functions through the processor installed in socket 1. However, if - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 75
To remove the air baffle: 1. Gently rock the air baffle up. 2. Take the air baffle out from the system board. Figure 34 Removing the Air Baffle To remove the heat sink: 1. Loosen the two spring-loaded screws. 2. Lift the heat sink away from the system board. CAUTION: Place the heat sink down in an - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 76
CAUTION: Do not over-tighten the spring-loaded screws to prevent them from breaking off. A maximum torque of 6 inch-lb is set for each screw. Rotate the heat sink a few degrees to the left and right to break the bonding of the thermal grease compound before removing the heat sink from the processor. - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 77
Figure 37 Removing the Processor 4. Carefully rotate the tool, and then push in and release the tabs to secure the processor in the tool. Figure 38 Removing the Processor CAUTION: To avoid damage to the processor, do not touch the bottom of the processor, especially the contact area. Removal and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 78
to the CPU contact surface. CAUTION: HP recommends using Shin-Etsu X-23-7783D thermal grease compound for your ProLiant server. 3. Apply new grease to the installation tool must be used to insert the processor into the socket. Instructions are provided in the Option Kits and spare part kits. To - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 79
Figure 40 Opening the lever and bracket IMPORTANT: Be sure the processor remains inside the processor installation tool. 2. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. Handle the processor by the edges only, and do not touch the bottom of - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 80
3. Be sure the tool is oriented correctly. Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. Figure 42 Installing the Processor CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 81
Figure 43 Removing the processor installation tool 5. Close the processor socket retaining bracket and the processor locking lever. Figure 44 Closing the processor socket CAUTION: Be sure to close the processor socket retaining bracket before closing the processor locking lever. The lever should - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 82
crash, use only a heat sink model specified for the HP ProLiant DL288 G6 server. To install the heat sink: 1. Properly align the server without the top cover, air baffle, expansion slot covers, or blanks installed. For additional information, see the user guide. If hot-plug components are supported - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 83
2P system, both physical processors must be of the same type and speed. • Use 800/1066/1333 MHz DDR3 RDIMM/UDIMM. • Supported DIMM capacity: 2 GB, 4 GB, 8 GB and 16 GB • Installation guide for 1P configuration: ○ Follow the sequence of 2A, 4B, 6C, 1D, 3E, and 5F for the corresponding processor when - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 84
Figure 48 DIMM Population Figure 49 DIMM Slots NOTE: Before installing the memory, remove the air baffle first. For a detailed procedure, see the "Processor" section in this chapter. Removal and replacement procedures 80 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 85
To remove the memory module: 1. Completely open the holding clips securing the memory module. 2. Gently pull the memory module upward to remove it from the slot. Figure 50 Removing the Memory Module CAUTION: Place the memory module on a static-dissipating work surface or inside of an anti-static bag - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 86
mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization. The memory subsystem may be populated with either RDIMMs or UDIMMs, but mixing the two types is not supported. To determine DIMM characteristics, use the label attached to the DIMM and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 87
board. Figure 53 System Board PCI Expansion Slots Item Component Designator 1 J31 2 J17 3 J18 Component Function PCIe x4 (FH/FL) slot 1b Supports a PCIe riser card or PCIe & PCI-X riser card PCIe x16 (FH/FL) slot 1a Supports a PCIe riser card or PCIe & PCI-X riser card PCIe x16 (LP) slot - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 88
PCIe x8 riser card, single PCIe x16 riser card, dual PCI-X riser card, or PCIe x16 & dual PCI-X riser card option kit. This will allow support for PCIe x8, PCIe x16, and PCI-X devices. Figure 54 Three PCIe x8 Riser Card Connector Location • Three slots PCIe riser card (Three x8 link - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 89
Figure 56 PCIe x16 Riser Card Connector Location • One slot PCIe riser card (x16 link with x16 slots) Removal and replacement procedures 85 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 90
PCI cage, the HDD PCI cage, the ODD PCI cage. The table below identifies the PCI cages by their function and shows their corresponding server type and supported riser cards. PCI cage Riser Card System model Standard PCI Cage Slot 1a&1b: dual PCIe x8 riser card for standard PCI cage; or - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 91
secures the PCI cage to the rear of the server. 2. Lift the PCI cage away from the system board. Figure 57 Removing the PCI Cage Installing PCIe riser card The system supports up to two riser cards at a time. Use only HP supported expansion boards that meet the following specifications: • Compliance - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 92
To remove the PCIe riser card: 1. Loosen the screw securing the riser card to the PCI cage. 2. Remove the riser card from the PCI cage. Figure 58 Removing the Three PCIe x8 Riser Card Figure 59 Removing the two PCIe x8 Riser Card Removal and replacement procedures 88 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 93
Figure 60 Removing the PCIe x16 Riser Card Removal and replacement procedures 89 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 94
To install the PCIe riser card: 1. Align the three riser card locking-tab holes to the corresponding standoffs on the PCI cage, and then push the card rightwards. 2. Tighten the screw that secures the riser card to the PCI cage. Figure 61 Installing the Three PCIe x8 Riser Card Figure 62 Installing - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 95
Figure 63 Installing the PCIe x16 Riser Card Removal and replacement procedures 91 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 96
To install the PCI expansion board: 1. Remove the screw near the slot cover on the PCI cage. Figure 64 Removing the Screw on the PCI Cage on the Full-height / Full-length Side Figure 65 Removing the Screw on the PCI Cage on the Low-profile Side Removal and replacement procedures 92 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 97
2. Remove the slot cover from the PCI cage. 3. Slide the expansion board into the slot, aligning the board with its matching connector. Firmly press the board to seat it properly on the slot. 4. Tighten the screw that secures the expansion board to the PCI cage. Figure 66 Installing the Three PCIe - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 98
Figure 68 Installing the PCIe x16 Expansion Board Removal and replacement procedures 94 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 99
To reinstall the PCI cage: The following figures show the front and back side of the backplane. Figure 69 Backplane Connectors / 2 3.5" HDD Model (component side) Item Description 1 Screw hole 2 LED indicators 3 Headers for hard drive Figure 70 Backplane Connectors / 2 3.5" HDD Model ( - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 100
Item 3 4 5 6 7 Description PIC PROG connector HDD 13 connector Power connector HDD 14 connector HDD LED connector 1. Install the PCI expansion board into the PCI cage. a. Align the PCI expansion board with the open expansion slot. b. Press the PCI expansion board into the expansion slot on the - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 101
To install the HDD PCI cage: 1. Loosen the thumbscrew and screws that secure the HDD PCI cage to the system board. 2. Lift the HDD PCI cage assembly away from the system board. Figure 72 Removing the HDD PCI Cage Assembly 3. Align the four backplane holes to the corresponding standoffs on the HDD - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 102
5. Align the HDD PCI cage assembly to the system board expansion slot, and then press it down to ensure full connection to the system board. 6. Tighten the thumbscrew to secure the HDD PCI cage assembly to the system board and secure the screws on the side and the rear panel of the chassis. Figure - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 103
8. Push the hard dive assembly into the drive bay until it stops. 9. Press the HDD carrier latch inward until it clicks. Figure 76 Installing the Rear Hard Drive To install the Optical Disc Drive PCI cage: 1. Loosen the thumbscrews that secure the optical disc drive PCI cage to the system board and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 104
3. Pushing the optical disc drive ROM into the ODD PCI cage. Figure 78 Pushing the optical disc drive DVD-ROM into the ODD PCI Cage 4. Tighten the screw that secures the optical disc drive to the ODD PCI cage. Figure 79 Securing the Optical Disc Drive Removal and replacement procedures 100 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 105
5. Align the ODD PCI cage assembly to the system board expansion slot, and then press it down to ensure full connection to the system board. 6. Tighten the thumbscrews to secure the ODD PCI cage assembly to the system board and secure the screw on the rear panel of the chassis. Figure 80 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 106
Dedicated management port (Optional) The server can support a dedicated management port. The dedicated management port is optional for the shipment. The following figure shows the dedicated management port location. Figure 81 Dedicated management port Location Removal and replacement procedures 102 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 107
To remove the dedicated management port: 1. Remove the PCI cage assembly out of the chassis. Refer to the "PCI cage" section in this chapter for detailed procedures. 2. Loosen the screw. 3. Pull the dedicated management port upwards, and then remove the dedicated management port from the dedicated - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 108
To reinstall the dedicated management port: 1. Remove the dedicated management port cover. Figure 84 Removing the Dedicated management Port Cover 2. Insert the spacer into the system board. Figure 85 Inserting the Spacer Removal and replacement procedures 104 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 109
clockwise to secure the dedicated management port to the system board. Figure 86 Reinstalling the Dedicated management port TPM Module (Optional) The server can support a TPM module. The TPM module is optional for the shipment. The following figure shows the TPM module location. Figure 87 TPM module - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 110
Figure 88 Removing the security rivet 2. Remove the TPM card from system board. Figure 89 Removing the TPM card To reinstall the dedicated management port: 1. Install the TPM card. Press down the TPM card to the connector to seat on the system board Removal and replacement procedures 106 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 111
2. Insert the TPM security rivet by pressing the rivet firmly into the system board Figure 91 Inserting security rivet System battery The server uses nonvolatile memory that requires a system battery to retain system information when power is removed. This 3 V lithium coin cell battery is located - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 112
the same type as the system battery recommended by HP. Use of another system battery may present a risk of used system battery according to manufacturer's instructions. CAUTION: Loss of BIOS settings occurs the system battery. NOTE: If the server no longer automatically displays the correct date - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 113
Figure 93 Replacing the System Battery Removal and replacement procedures 109 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 114
BBWC (Optional) The system board can support up to two BBWC. The BBWC is optional for the shipment. Figure 94 BBWC Locations To remove the BBWC: 1. Pull the BBWC retaining latch. 2. Slide the BBWC back, up and out of the tray. Figure 95 Removing the BBWC Removal and replacement procedures 110 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 115
To reinstall the BBWC: 1. Pull the BBWC retaining latch. 2. At the same time, align the locking tabs on the BBWC to their holes on the tray. Press the BBWC into the tray, and then push it along the direction of the arrow to lock the locking tabs. Figure 96 Reinstalling the BBWC Removal and - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 116
System board removal and replacement procedure To remove the system board: 1. Remove the top cover. 2. Loose the nine screws that secure the system board to the chassis. 3. Slide the system board back, up and out of the chassis. Remove the system board from the chassis. Figure 97 Removing the System - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 117
To reinstall the system board: 1. Align the system board I/O connectors to their openings and slide the system board into place. The nine screw holes on the chassis should align with the system board. 2. Fasten the nine screws on the system board to secure the system board to the chassis. Figure 98 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 118
shock hazards and/or damage to the equipment. • Installation of power supply units should be referred to individuals who are qualified to service server systems and are trained to deal with equipment capability of generating hazardous energy levels. • DO not open the power supply unit. There - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 119
Figure 100 Removing the Power Supply To reinstall the power supply: 1. Press the release tabs of the power supply blank, and then pull the power supply blank out of the chassis. Figure 101 Removing the Power Supply Blank 2. Align the hot-plug power supply cage connector with the open power supply - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 120
Figure 102 Reinstalling the Power Supply Removal and replacement procedures 116 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 121
System fan cage The server supports two kinds of fan cage. The system redundant fan cage is optional for shipment. • System non-redundant fan cage • System redundant fan cage Figure 103 System Non-redundant Fan Cage Figure 104 System Redundant Fan Cage Removal and replacement procedures 117 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 122
To remove the system non-redundant fan cage 1. Remove all screws on the system non-redundant fan cage. 2. Lift the system fan cage up and out of the chassis. Figure 105 Removing the System Non-redundant Fan Cage To remove the system redundant fan cage 1. Loosen the screws that secure the system - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 123
Figure 107 Reinstalling the System Non-redundant Fan Cage To install the system redundant fan cage 1. Get eight screws from the existing system non-redundant fan cage. See figure "Figure 105 " 2. Remove the foam on the system redundant fan cage. Figure 108 Removing the foam 3. The redundant fan kit - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 124
4. Locate the system fan cage on the chassis and vertical wall. 5. Fasten the screws. Figure 110 Installing the System Redundant Fan Cage 6. Install the foam on the system redundant fan cage. 7. Paste the mylar on the fan bracket. Figure 111 Installing the Foam and Mylar Removal and replacement - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 125
Removal and replacement procedures 121 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 126
has four or eight system fans located on the center wall of the chassis. While the server is equipped with eight system fans, the redundant function is provided. The figure below identifies the system fans by their device number and shows their - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 127
memory modules and processors, while system fan 7/8 is for the PCI slots and system chipsets. A new system fan can be installed to allow the server to operate properly in case a default system fan becomes defective. The installation and removal of fans on the system redundant fan cage and system - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 128
Figure 114 Removing the System Fan To reinstall the system fan: 1. Hold the system fan and press it into the system fan bracket. 2. Secure the cable using the cable clip located on the chassis partition wall. 3. Connect the system fan cable to its corresponding board connector. Figure 115 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 129
, switch, buttons, and LED indicators located on the front panel, rear panel, system board and hard drives of the HP ProLiant DL288 G6 server. Connectors and components Front panel components Figure 116 Front Panel Components / 4 3.5" HDD Model Item 1 2 3 4 5 6 7 8 9 10 11 Description Front panel - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 130
Item Description 12 Hard disk drive (HDD) bays Figure 117 Front Panel Components / 8 3.5" HDD Model Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Front panel USB 2.0 port 0/1 Optical disc drive Front UID LED/switch System health LED NIC 1 activity LED NIC 2 activity LED Hard drive activity LED - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 131
Figure 118 Front Panel Components / 8 2.5" HDD Model Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Front panel USB 2.0 port 0/1 Optical disc drive Front UID LED/switch System health LED NIC 1 activity LED NIC 2 activity LED Hard drive activity LED Power LED/switch Thumbscrews for rack mounting Drive - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 132
Figure 119 Front Panel Components / 12 3.5" HDD Model Item 1 2 3 4 5 6 7 8 9 10 11 Description Front panel USB 2.0 port 0/1 System health LED Front UID LED/switch NIC 1 activity LED NIC 2 activity LED Hard drive activity LED Power LED/switch Thumbscrews for rack mounting Drive online/error LED - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 133
Figure 120 Front Panel Components / 25 2.5" HDD Model Item 1 2 3 4 5 6 7 8 9 10 11 Description Front panel USB 2.0 port 0/1 System health LED Front UID LED/switch NIC 1 activity LED NIC 2 activity LED Hard drive activity LED Power LED/switch Thumbscrews for rack mounting Drive online/error LED - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 134
Rear panel components Figure 121 Rear Panel Components for Standard PCI Cage Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Power supply 2 cable socket Serial port T-10/T-15 wrench GbE LAN port for NIC 2 Dedicated management port (optional) Low-profile PCI expansion card slot cover Full-height/full- - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 135
Figure 122 Rear Panel Components for HDD PCI Cage Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Power supply 2 cable socket Serial port T-10/T-15 wrench GbE LAN port for NIC 2 Dedicated management port (optional) Low-profile PCI expansion card slot cover Hard disk drive (HDD) bay Rear UID LED/switch - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 136
Figure 123 Rear Panel Components for ODD PCI Cage Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Power supply 2 cable socket Serial port T-10/T-15 wrench GbE LAN port for NIC 2 Dedicated management port (optional) Optical disk drive (ODD) bay Full-height/full-length PCI expansion card slot covers - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 137
System board components Figure 124 System Board Components Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Designator Description J17 PCIe slot J11 Dedicated management port connector J18 PCIe slot J21 DIMM slot 6C for processor 2 J26 DIMM slot 1D for processor 2 CPU2 Processor - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 138
Item 21 22 23 24 25 26 27 28 29 Designator Description B1 3 V CMOS battery (CR2032) J76 Power backplane control connector J56 LCD connector (optional) J53 Front panel USB 2.0 port 0/1 J42 Front panel header J29 TPM connector J27 System maintenance jumper SATA SATA connectors J31 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 139
panel • Optical disc drive • Hard drive • Rear panel • System board These LED indicators aid in problem diagnosis by indicating the status of system components and operations of the server. Front panel LED indicators The front panel LED indicators allow constant monitoring of basic system functions - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 140
Table 22 Front Panel LED Indicator Status on the Right Ear Item LED indicator 3 Hard drive activity LED 4 Power LED/switch Status Flashing green Off Steady green Steady amber 5 NIC 1 activity LED 6 Front UID LED/switch Off Steady green Flashing green Off Steady blue Flashing blue Off - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 141
Hard drive LED indicator The status of hard drives installed in the server is indicated by the hard drive LED indicators located on the HDD. Figure 127 Hard Drive LED Indicator Table 24 Hard Drive LED Indicator Status - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 142
Rear panel LED indicators The LAN port on the rear panel has two LED indicators that allow monitoring of network activity. Figure 128 LAN LED Indicators Location Table 25 LAN LED Indicator Status Item 1 2 3 4 Component NIC activity LED indicator Status Flashing green Off NIC link LED indicator - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 143
System board LED indicator The system board contains one LED indicator for use during troubleshooting operations. Figure 129 System Board LED Indicator Table 26 BMC activity LED Indicator Status Item Component 1 BMC activity LED indicator Status Description Steady green BMC - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 144
components, allocate resource for various hardware devices, and prepare the system to boot to various operating systems. BIOS Setup Utility The HP server BIOS Setup Utility is used to configure five primary menu selections: • Main • Advanced • Boot • Security • Exit Accessing the BIOS Setup Utility - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 145
Navigating through the Setup Utility Use the keys listed in the legend bar on the right of the Setup screen to navigate through the various menu and submenu screens of the Setup Utility. Table 27 lists these legend keys and their respective functions. Table 27 Setup Utility Navigation Keys Key ← - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 146
menu Figure 130 Main Menu of the BIOS Setup Utility ROM-based Setup Utility Advanced Boot Security Exit System Overview Product Name: ProLiant DL288 G6 ProLiant BIOS: O20 Build Date: 01/26/2010 ROM ID 12DIM191 Use [ENTER], [TAB] or [SHIFT-TAB] to select a field. Use [+] or [-] to - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 147
F1 General Help F10 Save and Exit ESC Exit V02. 61(C) Copyright 1985-2006, American Megatrends, Inc. WARNING: Incorrect settings may cause the server to malfunction. To correct the settings, press the F9 key to restore the default settings. • CPU Configuration-Configure CPU settings. • CPU Bridge - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 148
Figure 132 IPMI Submenu of the BIOS Setup Utility ROM-based Setup Utility IPMI 2.0 Configuration Status of BMC Working BMC Firmware Revision 09.57 BMC/IPMI FW Date: Jan/13/2010 BMC SDR Version: 2.17.0.43 Warehouse Build Number XXX >Set LAN Configuration >SEL Configuration - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 149
priority settings for USB devices. Users can configure the BIOS to avoid attempting to boot non-bootable USB devices that are left plugged into the server during POST. The options are High (default) and Low. • Restore on AC Power Loss-Use this screen to restore the AC power loss. Diagnostic tools - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 150
Security menu Figure 134 Security Menu of the BIOS Setup Utility ROM-based Setup Utility Main Advanced Boot Exit Security Settings Admin Password: Not Installed User Password: Not Installed Install or Change the Password. Change Admin Password Boot Sector Virus Protection: [ - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 151
ESC Exit V02. 61(C) Copyright 1985-2006, American Megatrends, Inc. Use this menu to save changes or discard changes. When you save and exit, the server reboots. • Save Changes and Exit-Save the changes you have made and exit the BIOS Setup Utility. • Discard Changes and Exit-Exit the BIOS Setup - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 152
recent compatibility fixes. The latest BIOS version for your server can be downloaded from http://www.hp.com. Clear CMOS You may need to clear the the button. AC power must not be connected. 5. Perform the Post-installation instructions. 6. During POST, press F10 to access the Setup Utility. 7. Load - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 153
" where "xxx" is a unique number code that matches ODM system specific error documentation and may be a hexadecimal or decimal value. All Error messages describe the problems as shown below: Table 28 POST Error Messages Error code 10 00B 00C 003 005 040 041 048 120 122 150 160 192 193 194 - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 154
System may operate in PIC or Non-MPS mode. POST related troubleshooting Perform the following procedures when POST fails to run, displays error plugged in. • The power outlet to the server should be connected and works correctly. • The server and monitor are both turned on. The bicolour status - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 155
SETSYS utility SETSYS.EXE (DOS application) is the correct tool for setting the Serial Number/Asset Tag text on this server after a system board replacement has occurred. Once the Serial Number/Asset Tag text has been entered via SETSYS, populating the SMBIOS data, the system BIOS - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 156
physical and operating specifications for the HP ProLiant DL288 G6 server. Specifications include: System unit Table 29 Tylersberg-36D/ICH-10R ServerEngines Pilot 2 management controller HP NC362i GbE controller for NIC LO100i sideband support Integrated ICH10R SATA (6-port) Optional Optical Disc - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 157
Table 29 Hardware Specifications Item Status LED indicators Front panel Rear panel System board Power supply unit Thermal solution Components System Health LED NIC 1/2 activity LED Power Switch/LED Hard drive activity LED indicator UID Switch/LED UID LED LAN link status BMC Activity LED 460 W - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 158
Table 30 Physical Dimensions Item System board platform System board dimension Server dimensions (H x W x D) Rack Server weight Table 31 Environmental Specifications Item Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Altitude: - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 159
Table 32 Power Supply Specifications / 460 W Item Dimensions (H x W x D) Weight (approximate) Input requirements: Rated input voltage Normal line voltage Line frequency Rated input current BTU rating Power supply output power: Rated steady state power Maximum peak power Temperature range: Operating - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 160
Table 33 Power Supply Specifications / 750 W Item Temperature range: Operating Shipping Relative humidity: Operating Non-operating Description +5°C to +50°C -40°C to +85°C 5% to 95% relative humidity, non-condensing 5% to 95% relative humidity, non-condensing Physical and operating specifications - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 161
Index A AC power power-down procedures, 42 air baffle installing, 79 removing, 71 B backplane, 61 reinstalling, 68 removing, 68 battery replacement warnings, 108 BBWC reinstalling, 111 removing, 110 bezel blank removing, 53 BIOS Setup Utility accessing, 140 additional navigation keys, 141 menu bar, - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 162
symbol, 41 warning, 40 HP authorized reseller, 37 contact information, 37 technical support, 37 technical support requirements, 37 I improper 84 PCIe riser card installing, 87, 90 removing, 88 physical dimensions, 154 server, 154 system board, 154 Power Supply Specifications / 460 W, 155 Power Supply - HP ProLiant DL288 | HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 163
POST error indicators, 149 POST related troubleshooting, 150 recoverable POST errors, 149 SETSYS utility, 151 carriers spare part number, 22, 23, 25, 26, 29, 31, 32, 34, 35 server dimensions rack, 154 server warnings and cautions, 40 Setup Utility menu bar advanced menu, 143 boot menu, 145 exit menu,
HP ProLiant DL288 G6 Server
Maintenance and Service Guide
Part number 663204-001
First edition July 2011