HP ProLiant DL288 HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 148

BMC/IPMI FW Date, Serial Port Configuration

Page 148 highlights

Figure 132 IPMI Submenu of the BIOS Setup Utility ROM-based Setup Utility IPMI 2.0 Configuration Status of BMC Working BMC Firmware Revision 09.57 BMC/IPMI FW Date: Jan/13/2010 BMC SDR Version: 2.17.0.43 Warehouse Build Number XXX >Set LAN Configuration >SEL Configuration >Hardware Health Information >Watchdog Configuration >Serial Port Configuration InPut for Set LAN Configuration command. NOTE: Each question in this group may take considerable amount of time. ←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit V02. 61(C)Copyright 1985-2006, American Megatrends, Inc. • Status of BMC-Display the status of BMC. • BMC Firmware Revision-Display the current revision of the BMC firmware. • BMC/IPMI FW Date-Display the date of the BMC/IPMI firmware. • BMC SDR Version-Display the current version of the BMC SDR. • Set LAN Configuration-Set LAN settings. • SEL Configuration-Display and clear the BMC system event log. • Hardware Health Information-Set temperature and fan rotation rate. • Watchdog Configuration-Configure watch dog timer status. • Serial Port Configuration-Configure serial port connection settings. Diagnostic tools and setup utilities 144

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Diagnostic tools and setup utilities
144
Figure 132
IPMI Submenu of the BIOS Setup Utility
ROM-based Setup Utility
<Advanced>
IPMI 2.0 Configuration
Status of BMC
Working
BMC Firmware Revision
09.57
BMC/IPMI FW Date:
Jan/13/2010
BMC SDR Version:
2.17.0.43
Warehouse Build Number
XXX
>Set LAN Configuration
>SEL Configuration
>Hardware Health Information
>Watchdog Configuration
>Serial Port Configuration
InPut for Set LAN
Configuration command.
NOTE: Each question in
this group may take
considerable amount of
time.
←→
Select Screen
↑↓
Select Item
Enter Go to Sub Screen
F1
General Help
F10
Save and Exit
ESC
Exit
V02. 61(C)Copyright 1985-2006, American Megatrends, Inc.
Status of BMC
—Display the status of BMC.
BMC Firmware Revision
—Display the current revision of the BMC firmware.
BMC/IPMI FW Date
—Display the date of the BMC/IPMI firmware.
BMC SDR Version
—Display the current version of the BMC SDR.
Set LAN Configuration
—Set LAN settings.
SEL Configuration
—Display and clear the BMC system event log.
Hardware Health Information
—Set temperature and fan rotation rate.
Watchdog Configuration
—Configure watch dog timer status.
Serial Port Configuration
—Configure serial port connection settings.