HP ProLiant DL288 HP ProLiant DL288 G6 Server Maintenance and Service Guide - Page 153
POST error indicators, POST error descriptions
View all HP ProLiant DL288 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 153 highlights
POST error indicators When POST detects a system failure, it displays a POST error message. POST error descriptions When a non-fatal error occurs during POST, the screen will display an error message with the format "xxx-Error Identifier String" where "xxx" is a unique number code that matches ODM system specific error documentation and may be a hexadecimal or decimal value. All Error messages describe the problems as shown below: Table 28 POST Error Messages Error code 10 00B 00C 003 005 040 041 048 120 122 150 160 192 193 194 195 196 197 198 601 605 611 612 613 Description Floppy Controller Failure CMOS Memory Size Wrong RAM R/W test failed CMOS Battery Low CMOS Checksum Bad Refresh timer test failed Display memory test failed Password check failed $A0CCMOS Cleared by Jumper. Restore the Jumper and Continue... $A0CPassword Cleared By Jumper. Restore the Jumper and Continue... Processor failed BIST Processor missing microcode: L3 cache size mismatch CPUID, Processor stepping are different CPUID, Processor family are different Front side bus mismatch. System halted. CPUID, Processor Model are different Processor speeds mismatched Processor QPI speed mismatch detected. Error: BMC Not Responding BMC Has Detected Fatal Hardware Error Internal User Area Of BMC FRU Corrupted Controller Update 'boot block' Firmware Corrupted Controller Operational Firmware Corrupted Diagnostic tools and setup utilities 149