Installation Guide hp StorageWorks SAN Switch 2/32 Version 4.2.x Fourth Edition (May 2004) Part Number: AA-RTQVD-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN Switch 2/32 and SAN Switch 2/32 power pack models. - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 2
are set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. SAN Switch 2/32 Version 4.2.x Installation Guide Fourth Edition (May 2004) Part Number: AA-RTQVD-TE - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 3
HP Authorized Reseller 12 1 Overview 13 SAN Switch 2/32 Features 14 Firmware 14 Hardware 14 Port Side of the SAN Switch 2/32 15 Optical Ports 15 Fan Assembly Side of the SAN Switch 2/32 16 Optional Hardware Kits 17 2 Installing the SAN Switch 2/32 19 Unpack and Verify Carton Contents 20 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 4
the Firmware Version 62 Setting the Switch Date and Time 62 Displaying Switch Configuration Settings 63 SAN Switch 2/32 Diagnostics 63 Interpreting POST Results 63 Additional Diagnostic Tests 64 Field Replaceable Units 64 Power Supplies 64 Fan Assemblies 65 4 SAN Switch 2/32 Version - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 5
Information 78 C. Usage Restrictions 78 Battery Replacement Notice 79 C Electrostatic Discharge 81 Grounding Methods 82 Glossary 83 Index 95 Figures 1 Port side of the SAN Switch 2/32 19 2 Fan assembly side of the SAN Switch 2/32 20 SAN Switch 2/32 Version 4.2.x Installation Guide 5 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 6
cable 51 15 Inserting a cable into an SFP 57 16 LEDs on port side of SAN Switch 2/32 62 17 LEDs on non-port side of SAN Switch 2/32 65 18 Power supplies and fan assemblies locations 75 19 Power supplies and fan assemblies locations 76 20 ioscan output 98 21 ioscan -funC disk command output - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 7
tGouriadgeeWorks SAN Switch 2/32. ■ Maintain and operate the switch. This preface discusses the following topics: ■ Audience, page 8 ■ Related Documentation, page 8 ■ Conventions, page 8 ■ Rack Stability, page 11 ■ Getting Help, page 11 SAN Switch 2/32 Version 4.2.x Installation Guide 7 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 8
, such as Windows® 2000, Windows NT®, and IBM AIX ■ Web Tools Graphical User Interface (GUI), for configuring the switch via a supported Web browser Related Documentation For a list of related documents included with this product, see the Related Documents section of the HP StorageWorks Fabric OS - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 9
italic font> Blue, underlined sans serif font text, for example: http://www.hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following commentary, sidelights, or interesting points of information. SAN Switch 2/32 Version 4.2.x Installation Guide 9 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 10
systems marked with these symbols indicate the presence of multiple sources of power. WARNING: To reduce the risk to personal injury from electrical shock, remove all power cords to completely disconnect power from the power supplies and systems. 10 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 11
manually HP authorized service provider or access our website: http://www.hp.com. HP Technical Support In North America, call technical support at 1-800-652-6672, available 24 hours a day, 7 days a week. Note: For continuous quality improvement, calls may be recorded or monitored. SAN Switch 2/32 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 12
. HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com. 12 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 13
17 The HP StorageWorks SAN Switch 2/32 is offered in two configurations; the 2/32 and 2/32 power pack. Refer to the HP StorageWorks Fabric OS 4.2.x Release Notes for a complete list of management features enabled on your specific switch. Note: This guide refers to both models as the SAN Switch 2/32 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 14
feature-specific information. Firmware The SAN Switch 2/32 operates using FOS firmware version 4.2.x. The firmware supports: ■ An optional Security feature, which provides security mechanisms at all vulnerable points in a SAN fabric, from hosts to storage at the port, switch, and fabric levels - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 15
SAN Switch 2/32. 1 2 3 Overview 5 4 SHR-2568A 1 Serial port 4 Power switch 2 Fibre Channel 5 Ethernet port port 3 IP address label Figure 1: Port side of the SAN Switch 2/32 Optical Ports The Fibre Channel ports are numbered from left to right, with ports 0-15 in the lower row and ports 16 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 16
to the HP StorageWorks Fabric OS 4.2.x Features User Guide. Fan Assembly Side of the SAN Switch 2/32 Figure 2 shows the fan assembly side of the SAN Switch 2/32. This side houses the fans with corresponding LEDs, power supplies, and the port readiness LED. 1 2 3 4 1 Power supply 3 Power supply - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 17
Hardware Kits HP provides the optional hardware kits in support of the SAN Switch 2/32 shown in Table 2. Table 2: SAN Switch 2/32 Orderable Hardware ** 221691-B27** C7534A* C7534A* * Premerger HP part number ** Premerger Compaq part number SAN Switch 2/32 Version 4.2.x Installation Guide 17 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 18
Overview 18 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 19
Carton Contents, page 20 ■ Locating SAN Switch 2/32 Serial Numbers, page 23 ■ Installation Guidelines, page 23 ■ Setting Up the Switch as a Stand-alone Unit, page 25 ■ Installing the Switch in a Rack Using the SAN Switch Rack Mount Kit, page 26 ■ Connecting AC Power, page 38 ■ Power On Self-Test - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 20
Unpack and Verify Carton Contents Unpack and inspect the SAN Switch 2/32 carton contents as follows: 1. Inspect the shipping container for possible 3. Note: If any items are damaged or missing, please contact HP or an HP authorized reseller. 20 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 21
Mount Kit shown in Figure 3 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 1 3 2 Figure 3: Shipping carton contents SAN Switch 2/32 Version 4.2.x Installation Guide SHR-2570B 21 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 22
Contents Number 1 Item One HP StorageWorks SAN Switch 2/32 product accessories box containing: ■ One RS-232 Serial cable (convertible to an RJ-45 connector, by removing the adapter on the end of the cable) ■ Pouch containing rack mount hardware: - (14) #8-32 x 3/16-inch Phillips pan-head screw - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 23
Installing the SAN Switch 2/32 Locating SAN Switch 2/32 Serial Numbers Before contacting HP for technical support or service, obtain the three serial numbers located on the switch. Each serial number provides specific logistical information, identifying the device's manufacturing location. - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 24
air intake vents on the non-port side of the switch. ■ Verify that the ambient air temperature does not exceed 40° Celsius (104° Fahrenheit) while the switch is operating. Caution: Do not block air vents. The switch uses ambient air for cooling. 24 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 25
Place a rubber foot in each depression, with the adhesive side against the chassis, and press into place. Caution: HP recommends installing the rubber feet on the switch to help prevent the switch from accidentally sliding off the table or bench. SAN Switch 2/32 Version 4.2.x Installation Guide 25 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 26
the HP StorageWorks SAN Switch Rack Mount Kit supplied with your switch. The Rack Mount Kit installation requires one technician to install a SAN Switch. The following items are required to install the switch in a cabinet: ■ SAN Switch 2/32 ■ Power cables ■ #2 Phillips screwdriver ■ 7/16-inch wrench - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 27
head SEMS screw for use with the SAN Switch 2/32. Note: 8-32 x 5/16-inch Phillips pan-head SEMS screw graphic is not available for this release. (10) #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer (8) #10 alignment washer SAN Switch 2/32 Version 4.2.x Installation Guide 27 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 28
one of the following steps: - For an HP 10000 series or comparable EIA cabinet, assemble each of the two brackets with two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 adapter washers as shown in Figure 4. 28 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 29
rear mounting brackets (HP 10000 series or comparable EIA cabinet) - For an HP System/e rack, install each of the two rear mounting brackets with two #10-32 x 1/2-inch Phillips pan-head screws and two #10 alignment washers as shown in Figure 5. SAN Switch 2/32 Version 4.2.x Installation Guide 29 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 30
the SAN Switch 2/32 Figure 5: Installing the rear mounting brackets (HP System/e 20 hex nuts with captive star lock washers attached loosely as shown in Figure 6. Do not tighten them; the nuts will be tightened later in step 7 on page 37. 30 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 31
Installing the SAN Switch 2/32 Figure 6: Installing the outer rails (HP 10000 series or comparable EIA cabinet) SAN Switch 2/32 Version 4.2.x Installation Guide 31 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 32
x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 7. Figure 7: Assembling the outer rails (HP 10000 series or comparable EIA cabinet) 32 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 33
Installing the SAN Switch 2/32 - For an HP System/e cabinet, install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 alignment washers in the upper and lower hole locations of the right rail. Then install two #10-32 x 1/2-inch Phillips pan-head screws with - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 34
outer. Note that the SAN Switch mounts in the rack with its front, the port side, facing the back of the rack. The rear of the switch, the AC side, faces the front of the rack. 5. Assemble the two inner rails (one on each side) to the switch using the ten #8-32 x 3/16-inch Phillips pan-head screws - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 35
Installing the SAN Switch 2/32 Note: For factory integration only, tighten the #8-32 x 3/16-inch Phillips pan-head screw with thread lock and torque between 6 to 8 inch-pounds. Note: The plenum is a required part of this installation when the SAN switch 2/32 is installed in an HP 9000 or 10000 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 36
the switch into a rack (HP 10000 series or comparable EIA cabinet) Insert the switch into the rack and install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers, one on each side. See Figure 11 and Figure 12. 36 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 37
Tighten the nuts installed in substep a of step 4 on page 30. See Figure 6 on page 31. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock washer from either side of the rack uprights. SAN Switch 2/32 Version 4.2.x Installation Guide 37 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 38
power off). The switch automatically runs POST. WARNING: Do not connect the switch to the network until the IP address is correctly set. For instructions on setting the IP address, see "Configuring SAN Switch 2/32 Network Addressing" on page 39. 38 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 39
on how to configure the SAN Switch 2/32 addressing scheme. For instructions about configuring the switch to operate in a fabric containing switches from other vendors, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. SAN Switch 2/32 Version 4.2.x Installation Guide 39 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 40
information about the commands used in this procedure, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Requirements The following items are required for configuring and connecting the SAN Switch 2/32 in a network and fabric: ■ An unused IP address and corresponding subnetmask - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 41
instructions specific to HyperTerminal. If you are using a different application, consult that application's documentation. 6. Using HyperTerminal (or similar application), configure the port settings as follows: ■ Bits per second: 9600 ■ Databits: 8 ■ Parity: None ■ Stop bits: 1 SAN Switch 2/32 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 42
Installing the SAN Switch 2/32 ■ Flow control: None To configure port settings in a UNIX® environment, enter: tip /dev/ttyb -9600 7. Log in to the switch as the admin user. The default admin logon is admin and the default password is password. a. Issue the ipAddrSet command at the prompt. b. Enter - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 43
Web Tools application. Verify that the switch is not accessed from any other connections during the remaining steps. 4. Log in to the switch by Telnet as the admin user. The default admin logon is admin and the default password is password. SAN Switch 2/32 Version 4.2.x Installation Guide 43 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 44
HP StorageWorks SAN Switch 2/32 and HP StorageWorks Core Switch 2/64 always use Core Switch PID format 1. This parameter is always 1 and cannot be changed. Mixed Fabric Environment with Different Switch Platforms Fabric OS v2.6.2, v3.1.2, and v4.2.x introduced a new switch PID format: Extended Edge - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 45
Installing the SAN Switch 2/32 If Extended Edge PID is set (before a downgrade from the current Fabric OS release to an earlier Fabric OS release that does not support the Extended PID format), PID needs to be set back to a supported format, such as Core PID (format 1) or native PID (format 0). - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 46
to connect the SFPs and cables to SAN Switch 2/32 ports as required. Note: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks Fabric OS 4.2.x Features Guide. 1. Remove the shipping plug from the appropriate - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 47
to verify that the switch is running properly. 1. Access your browser. 2. At the URL address window, enter http://your switch IP address. 3. If connected properly, the name of your switch appears in green at the prompt, indicating Healthy/OK. SAN Switch 2/32 Version 4.2.x Installation Guide 47 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 48
instructions on how to back up the configuration, refer to Chapter 4, "Backing Up Configuration Data and Upgrading Firmware." Or, for more detailed information and commands, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. Installing Multiple Switches into an Existing SAN Execute - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 49
HP StorageWorks Fabric OS 4.2.x Features User Guide. ■ Label the fiber optic cables and record the devices to which they are connected. ■ Keep LEDs visible by routing port is 2 inches under full tensile load, and 1.2 inches with no tensile load. SAN Switch 2/32 Version 4.2.x Installation Guide 49 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 50
Installing the SAN Switch 2/32 50 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 51
32 3 This chapter discusses the following topics: ■ Interpreting LED Activity, page 52 ■ Management Overview, page 58 ■ Running Basic Switch Operations Using Telnet, page 60 ■ SAN Switch 2/32 Diagnostics, page 63 ■ Field Replaceable Units, page 64 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 52
about the error log, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. LEDs on the Port Side of the Switch The port side of the switch contains the following LEDs; see Figure 17: ■ One Switch Power/Status LED on right side ■ One Port Status LED next to each Fibre Channel - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 53
Managing the SAN Switch 2/32 Table 5 describes the LEDs on the port side of the switch. Table 5: Front Panel LED Patterns During Normal Operation LED Name and Location Switch Power/ Status LED LED Location On far right when viewing switch from port side Color Display No light Steady green - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 54
to port, and switch and port settings are correct. No action required. No action required. No action required. No action required. Reset the switch from a management station. 1. Check transceiver and cable or loopback plugs for correct insertion. 2. Check and clear error log. 54 SAN Switch 2/32 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 55
the top of each fan assembly (inside the bezel) 1 2 3 SHR-2579A 1 Power supply LED 2 Fan failure LED 3 Port readiness LED Figure 18: LEDs on non-port side of SAN Switch 2/32 Table 6 describes the LEDs on the non-port side of the switch. SAN Switch 2/32 Version 4.2.x Installation Guide 55 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 56
log, Port Status LEDs, transceivers, cables, and loopback plugs. 2. Correct error condition. 3. Clear error log. 4. Rerun diagnostics to verify fix. Verify power supply is on and seated, and power cord is connected to a functioning power source. 56 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 57
or is not receiving power. Flashing orange (on 1 second; off 1 second) Fan assembly has failed. Recommended Action No action required. Verify power supply is on and power cord is connected to a functioning power source. Replace fan assembly. SAN Switch 2/32 Version 4.2.x Installation Guide 57 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 58
7. Note: For information about upgrading the version of Fabric OS installed on the switch, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. Table 7: Management Options for the SAN Switch 2/32 Management Tool Command Line Interface (CLI) Runs up to two admin sessions and four - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 59
Managing the SAN Switch 2/32 Table 7: Management Options for the SAN Switch 2/32 (Continued) Management Tool Management server Refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide and the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Out-of-band Support Ethernet or Serial - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 60
a password to access the management via the serial line. With version 4.0.0 and later, a password is required to use the serial line, similar to using the admin level Telnet or admin level Web Tools. 1. Log in to the switch as the admin user. 60 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 61
7. Press Enter to commit the configuration to the firmware. Note: Save your passwords in a safe place. It is nearly impossible to access a switch without knowing the switch password. Configuring the IP and Fibre Channel Address The SAN Switch 2/32 is shipped with a default IP address of 10.77.77.77 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 62
command. This command displays all the connected devices in the fabric. Checking the Firmware Version Follow these steps to display the SAN Switch 2/32 firmware version. 1. Log in to the switch as the admin user. 2. Issue the version command. This command displays the Kernel version and Fabric OS - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 63
to your switch supplier for repair. Any errors detected during POST are written to the system log, accessible through the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. SAN Switch 2/32 Version 4.2.x Installation - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 64
cords. To remove all power from the switch, disconnect both power cords before servicing. Power Supplies The two power supplies are hot-swappable if replaced one at a time. They are identical and fit into either power supply slot; see Figure 19. 64 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 65
switch. ■ Issue the psshow command. ■ In Web Tools, click the Power Status icon. Fan Assemblies The three fan assemblies are hot-swappable if replaced one at a time. The fan assemblies are identical and fit into any fan assembly slot; see Figure 20. SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 66
replacing, first check the Switch Power/Status and Port Status LEDs. Next, run diagnostics (refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide). If the motherboard assembly appears to require replacing, contact your switch supplier. 66 SAN Switch 2/32 Version 4.2.x Installation - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 67
discusses the following topics: ■ Backing Up System Configuration Settings, page 68 ■ Restoring the System Configuration Settings, page 69 ■ Upgrading or Restoring Switch Firmware, page 69 ■ Downloading Firmware from the HP Website, page 70 SAN Switch 2/32 Version 4.2.x Installation Guide 67 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 68
system prompts you for each parameter, as follows: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 68 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 69
, path_filename is the path location and filename of the new firmware file, and password is the password for the user ID specified. The password operand is required only if you are using FTP. 4. Reboot the switch by issuing the fastBoot command. SAN Switch 2/32 Version 4.2.x Installation Guide 69 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 70
and Upgrading Firmware Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. This website provides the required loaders and instructions for downloading the firmware to a switch. 70 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 71
Technical Specifications This appendix covers the following topics: ■ Dimensions, page 72 ■ Power Supply Specifications, page 72 ■ Environmental Requirements, page 73 ■ Memory Specifications, page 73 ■ Serial Port Specifications, page 74 A SAN Switch 2/32 Version 4.2.x Installation Guide 71 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 72
SAN Switch 2/32 dimensions. Table 8: Physical Specifications Dimension Height Depth Width Weight (with both power supplies) Value 2.58 in (65.5 mm) 23.06 in (585.6 mm) 16.87 in (42.86 cm) 35.8 lb (16.2 kg) Power lines, using independent fuses 72 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 73
■ Flash Memory: 32 MB ■ Boot Flash: 512KB of 8-bit for system boot ■ Compact Flash: 256 MB The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times. SAN Switch 2/32 Version 4.2.x Installation Guide 73 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 74
supported; if pin 7 is used, the signal must always be driven high, using the pinouts listed in Table 11. .Table 11: Cabling Pinouts if Pin 7 is Used PIN 1 2 3 4 5 6 7 8 9 Signal Description TxData RxData Transmit Data Receive Data GND Logic Ground CTS Clear to Send 74 SAN Switch 2/32 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 75
Statement (Japan), page 77 ■ BSMI EMC Statement (Taiwan), page 77 ■ RRL EMC Statement (Korea), page 77 ■ Laser Safety, page 78 ■ Battery Replacement Notice, page 79 B SAN Switch 2/32 Version 4.2.x Installation Guide 75 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 76
with the instruction manual, may user may be required to take adequate measures. Germany Noise Declaration Schalldruckpegel Lp = 46.1 dB(A)Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprüfung) 76 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 77
VCCI EMC Statement (Japan) BSMI EMC Statement (Taiwan) RRL EMC Statement (Korea) Regulatory Compliance Notices SAN Switch 2/32 Version 4.2.x Installation Guide 77 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 78
Certificate (Worldwide) B. Product Information Each communications port consists of a transmitter and receiver optical not considered hazardous. WARNING: There are no user maintenance operations, service operations, or adjustments to be performed on SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 79
packs, and accumulators should not be disposed of with the general household waste. In order to forward them to recycling or proper disposal, please use the public collection system or return them to HP, your authorized HP partners, or their agents. SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 80
Regulatory Compliance Notices 80 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 81
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Switch 2/32 Version 4.2.x Installation Guide 81 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 82
conductive field service tools. ■ Use a portable field service kit with HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 82 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 83
port. Alias Server A fabric software facility that supports multicast group management. API Application Programming Interface; defined protocol that allows applications to interface with a set of services before beginning loop initialization. SAN Switch 2/32 Version 4.2.x Installation Guide 83 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 84
between two ports. Consists of two virtual circuits capable of transmitting in opposite directions. See also Link. Command Line Interface that depends entirely on the use of commands, such as through telnet or SNMP, and does not involve a GUI. 84 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 85
; the number of receive buffers allocated by a recipient port to an originating port. Used by Class 1 and 2 services to manage the exchange of frames across the fabric between source and destination. See also End-to-end Flow Control, BB_Credit. SAN Switch 2/32 Version 4.2.x Installation Guide 85 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 86
F_Port Fabric Port; a port that is able to transmit under fabric protocol and interface over links. Can be used to connect an N_Port to a switch. Fabric A protocol service that supports communication between Fibre Channel service providers. 86 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 87
Channel. Set the gateway address on one switch to the Fibre Channel IP address of another switch to enable the other switch to forward IP traffic to the Ethernet port on the second switch. Gbps Gigabits per second (1,062,500,000 bits/second). SAN Switch 2/32 Version 4.2.x Installation Guide 87 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 88
required to transmit a frame, from the time it is sent until it arrives. Link Services A protocol for link-related actions. Link As applies to Fibre Channel, a physical connection between two ports, consisting of both transmit and receive fibres. 88 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 89
that wins arbitration in an arbitrated loop and sends an OPN ordered set to the destination port, then enters the Open state. Open Recipient The L_Port that receives the OPN ordered set from the open originator, and then enters the Open state. SAN Switch 2/32 Version 4.2.x Installation Guide 89 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 90
port. Communicated during login and port discovery. POST Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports arbitrated and can communicate with either private or public NL_Ports. 90 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 91
support 20-bit addresses (or has 20-bit phantom addresses created for it by the switch The assignment of frames to specific switch ports, according to frame destination. RR_TOV Service Rate The rate at which an entity can service requests. SAN Switch 2/32 Version 4.2.x Installation Guide 91 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 92
with multiple ports without reentering the arbitration cycle for each circuit. This state can only be accessed by an L_Port in the Open state. Translative Mode A mode in which private devices can communicate with public devices across the fabric. 92 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 93
a specific function in the fabric. UDP User Datagram Protocol; a protocol that runs on top of IP and provides port multiplexing for upper-level protocols. ULP_TOV Upper- the loop. A port in the XMITTED CLOSE state cannot attempt to arbitrate. SAN Switch 2/32 Version 4.2.x Installation Guide 93 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 94
partitioning of the fabric into logical groupings of devices. Devices in a zone can only access and be accessed by devices in the same zone. 94 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 95
channel address 61 connecting 43, 46 connecting AC power 38, 40 conventions document 9 SAN Switch 2/32 Version 4.2.x Installation Guide Index Index equipment symbols 10 text symbols 9 cooling requirements 24 D diagnostic tests about 64 displaying the fabric wide device count 62 displaying the - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 96
related documentation 8 required equipment 40 requirements cooling 24 environmental 73 power 25 shock and vibration 73 temperature and humidity 73 restoring 69 restoring switch firmware 69 restoring the system configuration settings 69 RS-232 port 41 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 97
73 tests, diagnostic 64 text symbols 9 U upgrading or restoring the switch firmware 69 V verifying operation 47 voltage 25 W warning rack stability 11 symbols on equipment 10 websites HP storage 12 weight, switch 72 Z zoning summary 14 SAN Switch 2/32 Version 4.2.x Installation Guide Index 97 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 98
Index 98 SAN Switch 2/32 Version 4.2.x Installation Guide - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 99
Index SAN Switch 2/32 Version 4.2.x Installation Guide 99 - HP StorageWorks 2/32 | HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 100
Index 100 SAN Switch 2/32 Version 4.2.x Installation Guide
Installation
Guide
hp
StorageWorks
SAN Switch 2/32
Version 4.2.x
Fourth Edition (May 2004)
Part Number:
AA-RTQVD-TE
This installation guide provides basic procedures for setting up, configuring, and managing the
SAN Switch 2/32 and SAN Switch 2/32 power pack models.