HP StorageWorks 2/32 HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 73
Environmental Requirements, Memory Specifications, Main Memory SDRAM: 128 MB per switch
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Technical Specifications . Environmental Requirements Table 10 lists the environmental ranges that are acceptable when the switch is operating, and the acceptable ranges when the switch is not operating. .Table 10: Environmental Requirements Condition Temperature (operating) Temperature (non-operating) Humidity (operating) Humidity (non-operating) Altitude (operating) Altitude (non-operating) Shock (operating) Shock (non-operating) Acceptable Range 10×C to 40×C -25×C to 70×C 20% to 85% RH non condensing, at 40×C, with maximum gradient with 10% per hour 10% to 850% RH non-condensing, at 70°C 0 to 3 km above sea level 0 to 12 km above sea level 80 G, 2.4 ms, half sine 20 G, 11 ms, half sine wave Memory Specifications The switch utilizes the following memory. ■ Main Memory (SDRAM): 128 MB per switch ■ Flash Memory: 32 MB ■ Boot Flash: 512KB of 8-bit for system boot ■ Compact Flash: 256 MB The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times. SAN Switch 2/32 Version 4.2.x Installation Guide 73