HP StorageWorks 2/32 HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide - Page 63

Displaying Switch Configuration Settings, SAN Switch 2/32 Diagnostics, Interpreting POST Results

Page 63 highlights

Managing the SAN Switch 2/32 - hh is the hour; valid values are 00-23. - mm is minutes; valid values are 00-59. - YY is the year; valid values are 00-99. Note: Year values greater than 69 are interpreted as 1970-1999; year values less than 70 are interpreted as 2000-2069. The date function does not support daylight saving time or time zones. Displaying Switch Configuration Settings Follow these steps to display the system configuration settings. 1. Log in to the switch as the admin user. 2. Issue the configShow command. The system configuration settings display. SAN Switch 2/32 Diagnostics This section provides information on using POST and diagnostic tests. Interpreting POST Results Each time the switch is powered on or reset, the switch automatically performs POST, a one-minute system check during which the port status LEDs flash different colors. To determine whether POST completed without errors, verify that all LEDs return to a normal state after POST is complete. If one or more LEDs do not return to a normal state, and this is not due to the switch being set to beacon, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. Note: If the switch prompt does not display when POST completes, POST did not successfully complete. The switch should be returned to your switch supplier for repair. Any errors detected during POST are written to the system log, accessible through the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS 4.2.x Procedures User Guide. SAN Switch 2/32 Version 4.2.x Installation Guide 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

Managing the SAN Switch 2/32
63
SAN Switch 2/32 Version 4.2.x Installation Guide
hh
is the hour; valid values are 00–23.
mm
is minutes; valid values are 00–59.
YY
is the year; valid values are 00–99.
Note:
Year values greater than 69 are interpreted as 1970
1999; year values less
than 70 are interpreted as 2000
2069. The date function does not support daylight
saving time or time zones.
Displaying Switch Configuration Settings
Follow these steps to display the system configuration settings.
1.
Log in to the switch as the admin user.
2.
Issue the
configShow
command.
The system configuration settings display.
SAN Switch 2/32 Diagnostics
This section provides information on using POST and diagnostic tests.
Interpreting POST Results
Each time the switch is powered on or reset, the switch automatically performs
POST, a one-minute system check during which the port status LEDs flash
different colors.
To determine whether POST completed without errors, verify that all LEDs return
to a normal state after POST is complete. If one or more LEDs do not return to a
normal state, and this is not due to the switch being set to beacon, refer to the
HP
StorageWorks Fabric OS 4.2.x Procedures User Guide
.
Note:
If the switch prompt does not display when POST completes, POST did not
successfully complete. The switch should be returned to your switch supplier for repair.
Any errors detected during POST are written to the system log, accessible through
the
errShow
command. For more information about error messages, refer to the
HP StorageWorks Fabric OS 4.2.x Procedures User Guide
.