Lexmark E360d Service Manual - Page 125
-430, Re-installation note, side frame.
View all Lexmark E360d manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
4513-420, -430 Re-installation note: • Prop open the duplex door, and insert the hook end of the spring hook through the frame opening (C) from the controller board side. Extend the hook until the sensor connector can be hooked. • Hook the spring hook (D) to the connector (E), and pull it through the opening. CD E • Place the sensor into position, and reconnect the cable on the controller board. • Using the spring hook, be sure to reroute the cable through the three retainers (F) between the sensor and side frame. F Note: If the cable is not properly installed in its retainers, then the loose cable will obstruct the paper path. Repair information 4-43
Repair information
4-43
4513-420, -430
Re-installation note:
•
Prop open the duplex door, and insert the hook end of the spring hook through the frame opening (C) from
the controller board side. Extend the hook until the sensor connector can be hooked.
•
Hook the spring hook (D) to the connector (E), and pull it through the opening.
•
Place the sensor into position, and reconnect the cable on the controller board.
•
Using the spring hook, be sure to reroute the cable through the three retainers (F) between the sensor and
side frame.
Note:
If the cable is not properly installed in its retainers, then the loose cable will obstruct the paper path.
E
D
C
F