Canon PowerShot 350 Service Manual - Page 70

determined

Page 70 highlights

Part 3: Repair Information 5) Return to the normal mode. CMD $28 ADR $E01A DATA $0 ADJUSTMENT (PS) 1) Set the camera in TEST mode. CMD $28 ADR $E01A DATA $2 2) Input following data to the camera. RET RET CMD $60 ADR DATA $85 RET 3) Search for a point where blooming does not occur with the up and down cursor keys. 4) When the point where blooming does not occur is determined, record the data. 5) Input the data recorded at 4) to EEPROM. (Factory data: Min: $6E, Max: AO) CMD $38 ADR sic DATA The data recorded at 4). RET 6) Return to the normal mode. CMD $28 ADR $E01A DATA RET 7) Turn the power off and on. 3-20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139

Part
3:
Repair
Information
5)
Return
to
the
normal
mode.
CMD
$28
ADR
$E01A
DATA
$0
RET
ADJUSTMENT
(PS)
1)
Set
the
camera
in
TEST
mode.
CMD
$28
ADR
$E01A
DATA
$2
RET
2)
Input
following
data
to
the
camera.
CMD
$60
ADR
DATA
$85
RET
3)
Search
for
a
point
where
blooming
does
not
occur
with
the
up
and
down
cursor
keys.
4)
When
the
point
where
blooming
does
not
occur
is
determined,
record
the
data.
5)
Input
the
data
recorded
at
4)
to
EEPROM.
(Factory
data:
Min:
$6E,
Max:
AO)
CMD
$38
ADR
sic
DATA
The
data
recorded
at
4).
RET
6)
Return
to
the
normal
mode.
CMD
$28
ADR
$E01A
DATA
RET
7)
Turn
the
power
off
and
on.
3-20