Canon PowerShot 350 Service Manual - Page 90

Flash, Adjustment

Page 90 highlights

Part 3: Repair Information 3.15 FLASH ADJUSTMENT PURPOSE" Adjusting the Flash to proper output. CAUTION: Shutter cannot to be released without inserting the card. STANDARD: Pedestal level minus Peak: 540±50mV Toms: • Data Transfer Unit • 18% Standard Reflection Board • Oscilloscope PREPARATION: 1) Position the tools as shown on the right. 18% Gray chart 1.5m To Oscilloscope To Data Transfer unit To AC Adaptor Fig. 3-48 SetUp 2) Set the Flash in TEST mode. CMD $28 ADR $E01A DATA $320 RET CMD $28 ADR $E114 DATA $78 RET CMD $20 ADR $E0F4 DATA $0 RET CMD $28 ADR $E106 DATA $400 RET 3-40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139

Part
3:
Repair
Information
3.15
FLASH
ADJUSTMENT
PURPOSE"
Adjusting
the
Flash
to
proper
output.
CAUTION:
Shutter
cannot
to
be
released
without
inserting
the
card.
STANDARD:
Pedestal
level
minus
Peak:
540±50mV
Toms:
Data
Transfer
Unit
18%
Standard
Reflection
Board
Oscilloscope
PREPARATION:
1)
Position
the
tools
as
shown
on
the
right.
18%
Gray
chart
1.5m
To
Data
Transfer
unit
To
Oscilloscope
To
AC
Adaptor
2)
Set
the
Flash
in
TEST
mode.
Fig.
3-48
SetUp
CMD
$28
ADR
$E01A
DATA
$320
RET
$28
$E114
$78
CMD
ADR
DATA
RET
$20
$E0F4
$0
CMD
ADR
DATA
RET
$28
$E106
$400
CMD
ADR
DATA
RET
3-40