Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 150
Compaq Options ROMPaq utility, Disk Port Address
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 150 highlights
Diagnostics and Troubleshooting 6-23 Table 6-2 POST Error Messages continued Error Code Audible Beeps 1768-Slot x Drive None Array-Resuming logical drive expansion process. 1769-Slot x Drive None Array - Drive(s) disabled due to failure during expand. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re- enable logical drives. 1770-Slot X Drive None Array - Critical Drive Firmware Problem Detected - Please upgrade firmware on the following drive(s) using Options ROMPaq (available from www.compaq.com): SCSI Port Y SCSI ID Z (RESUME = F1 OR F2 KEY) 1771-Primary Disk None Port Address Assignment Conflict 1772-Secondary None Disk Port Address Assignment Conflict 1773-Primary Fixed None Disk Port Assignment Conflict 1774-Slot X Drive None Array - Obsolete data found in Array Accelerator. Select F1 to discard contents of Array Accelerator. Select F2 to write contents of Array Accelerator to drives. Probable Source of Problem SMART-2 Controller error detected. SMART-2 Controller error detected. Recommended Action No action required. Appears whenever a controller reset or power cycle occurs while array expansion is in progress. Data has been lost while expanding the array; therefore, the drives have been temporarily disabled. Press F2 to accept the data loss and reenable the logical drives. Restore data from backup. Firmware update need indicated. The indicated drives are running firmware that is known to cause intermittent problems. Use the Compaq Options ROMPaq utility to upgrade firmware on all drives to the latest revision. Acquire from the Compaq website: http://www.compaq.com/ support Internal and external hard drive controllers are both assigned to the primary address. Address Assignment Conflict. Internal and external hard drive controllers are both assigned to the secondary address. Fixed disk drive error detected. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. SMART-2 Controller error detected. Data found in array accelerator is older than data found on drives. Press F1 to discard the older data in the array accelerator and retain the newer data on the drives. continued