Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 151
Port Y: Check storage, RESUME = F1 Key
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
6-24 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-2 POST Error Messages continued Error Code Audible Beeps 1775-Slot X Drive None Array - ProLiant Storage System Not Responding SCSI Port Y: Check storage system power switch and cables. Turn the system power off while checking the ProLiant power and cable connections, then turn the system power back on to retry. 1776-Slot X Drive None Array - SCSI Bus Termination Error - Internal and external drives cannot both be attached to the same SCSI port. SCSI port Y: Check cables RESUME = F1 Key Probable Source of Problem Storage system problem detected. Recommended Action Turn off power to system. Check external ProLiant power switch - external drives must all be powered up before or at the same time as the main system. Check cables. If retry does not help, try replacing the cable, firmware, backplane, or the Smart Array Controller. External and internal connectors of the specified SCSI ports are both attached to drives. The indicated SCSI bus is disabled until this problem is resolved. The SCSI bus is not properly terminated when internal and external drives are attached concurrently to the same SCSI bus. 1. Turn off power to the server. 2. Verify cabling to the specified port. 3. Reconfigure drives as indicated. continued