Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 167
Serial Test Error Codes, Modem Communications Test Error Codes, Table 6-9
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
6-40 Compaq ProLiant 8000 Servers Maintenance and Service Guide 1100 - 1199, Serial Test Error Codes The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board or system board functions. Table 6-9 Serial Test Error Codes Error Code 1101-xx 1109-xx Description Serial port test failed. Clock register test failed. Recommended Action The following steps apply to error codes 1101-xx through 1109-xx. 1. Check the switch settings on the serial/parallel interface board (if applicable) and retest. 2. Replace the serial/parallel interface board (if applicable) and retest. 3. Replace the system board and retest. 1200 - 1299, Modem Communications Test Error Codes The 1200 series of diagnostic error codes identifies failures with the modem. Table 6-10 Modem Communications Test Error Codes Error Code 1201-xx 1202-xx 1203-xx 1204-xx 1206-xx 1210-xx Description Modem internal loopback test failed. Modem time-out test failed. Modem external termination test failed. Modem auto originate test failed. Dial multi-frequency tone test failed. Modem direct connect test failed. Recommended Action The following steps apply to error codes 1201-xx through 1210-xx. 1. Refer to the modem documentation for correct setup procedures and retest. 2. Check the modem line and retest. 3. Replace the modem and retest.