Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 185
SOLUTION: This, power down
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
6-58 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-16 ADU Diagnostic Messages continued Message Description Storage enclosure on SCSI bus X - Wide SCSI transfer failed. A cable on bus X has failed. SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable. Swapped cables or Configuration error detected. A configured array of drives was moved from another controller that supported more drives than this controller supports. You have exceeded the maximum number of drives supported for this controller and the attached controller was not part of the original array configuration. SOLUTION: Upgrade the firmware on this controller. If this doesn't solve the problem, then power down system and move the drives back to the original controller. Recommended Action 1. Replace the failed cable. 2. If that does not solve the problem, contact your Compaq authorized service provider. 1. Upgrade the firmware on this controller. 2. If the problem is not resolved: Replace this controller with the original controller. -OrReplace this controller with a new controller that supports the number of drives in the array. continued