Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 159
Select F1 to, Drives Disabled due
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
6-32 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-2 POST Error Messages continued Error Code Audible Beeps 1799-Drive Array - None Drive(s) Disabled due to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re-enable logical drives. 1800-Temperature None Alert Probable Source of Problem Volume failed due to loss of data in posted-writes memory. Recommended Action Press F1 to continue with logical drives disabled or F2 to accept data loss and re-enable logical drive. System has exceeded allowable temperature thresholds. 1. Turn system off and allow it to cool. 2. Check fans for proper airflow and obstructions. 3. Check fans for proper operation. 4. Analyze ambient temperature in which the server is currently operating, and compare to user documentation recommendations. 5. Adjust as needed before restarting the server.