Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 176
Run the System Configuration Utility to initialize, for SCSI Port X
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 176 highlights
Diagnostics and Troubleshooting 6-49 Table 6-16 ADU Diagnostic Messages continued Message Description Drive (bay) X is a replacement drive marked OK This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure. For example, if a drive has previously failed, then when ADU is run, the drive starts working again. Drive (bay) X is failed The indicated physical drive has failed. Drive (bay) X is undergoing drive recovery This drive is being rebuilt from the corresponding mirror or parity data. Drive (bay) X needs replacing The 210-megabyte hard drive has firmware version 2.30 or 2.31. Drive (bay) X upload code not readable An error occurred while ADU was trying to read the upload code information from this drive. Drive (bay) X was inadvertently replaced The physical drive was incorrectly replaced after another drive failed. Drive Monitoring features are unobtainable Drive Monitoring is NOT enabled for SCSI Port X Drive ID Y Drive time-out occurred on physical drive bay X Drive X indicates position Y Duplicate write memory error ADU unable to get monitor and performance data due to fatal command problem (such as drive time-out) or unable to get data due to these features not supported on the controller. The monitor and performance features have not been enabled on this drive. ADU issued a command to a physical drive and the command was never acknowledged. Message indicates a designated physical drive, which appears to be scrambled or in a drive bay other than the one for which it was originally configured. Data could not be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a data loss situation. Recommended Action Replace the drive. Replace the drive. Normal operations should occur. Replace the drive. If there were multiple errors, this drive may need to be replaced. 1. Replace the drive that was incorrectly replaced. 2. Replace the original drive that failed. Do not run the System Configuration Utility and try to reconfigure; data will be lost. Check for other errors such as time-outs. If no other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Run the System Configuration Utility to initialize the monitor and performance features. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Examine the graphical drive representation on ADU to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the ADU instructions. Replace the array accelerator board. continued